Delta AHCPU531-RS2

Delta AHCPU531-RS2 Advanced AH500 PLC CPU

Delta AHCPU531-RS2 is an advanced CPU for the Delta AH500 rack-based PLC system. It provides 384K program steps and supports up to 4,352 physical I/O points with a suitable rack and module configuration. With two serial ports, Mini USB and an SD card slot, it is suited to multi-rack control projects in the Delta AH PLC series.

Manual and port layout

AHCPU531-RS2 specifications (PDF, English) · Printed pages 2-6 to 2-8 of the AH500 Hardware & Operation Manual.

RS2 front panel and ports (PDF, English) · Printed page 2-9 of the same manual shows COM1, COM2, Mini USB and the SD slot.

All Delta AH PLC PDF files

Program memory and rack capacity

The CPU provides data registers D0–D131071 and 8 MB of function block memory. Delta specifies up to 68 modules across one main rack and seven expansion racks. When planning slots and power, account for AH expansion modules, digital I/O and analog I/O rack by rack.

For power supply selection, compare the input voltage and rack capacity of the AHPS05-5A and AHPS15-5A in the AH power supply range.

Serial communication and ISPSoft connection

The COM1 and COM2 serial ports support RS-232, RS-422 and RS-485. Before connecting a field device, verify the COM port, pinout, baud rate and parity used in the project. For racks that need additional serial links, see the AH10SCM-5A serial communication module.

Use a Mini USB data cable for the PC connection. After installing the USB driver, select the connection in COMMGR. Use HWCONFIG in ISPSoft to check the rack, module order and I/O addresses. Setup resources are in the Delta PLC software section.

Editor’s note

When buying a used CPU, check the full AHCPU531-RS2 code on the label. Match the RS2 suffix to the order.

Inspect the rear rack connector, mounting screw and Mini USB socket. A loose socket can interrupt the online connection.

On a compatible bench rack, power up the CPU, watch the RUN, ERROR and BUS FAULT indicators, and read the CPU information in ISPSoft.

Before removing a CPU from an existing machine, back up the program, hardware configuration and serial port settings.

If the replacement CPU cannot communicate with the field devices, compare the COM1/COM2 selection and serial parameters against the backup before changing the cable.

Related topics

The AHCPU530-RS2 supports the same 4,352 physical I/O points with 256K program steps. For smaller rack configurations, see the AHCPU521-RS2 and AHCPU511-RS2. For projects that require built-in Ethernet, check the port layout of the AHCPU531-EN. For rack and cable selection, see Delta PLC accessories.

Browse · Delta Automation · Delta PLC

External reference

Delta AH500 Hardware & Operation Manual