Delta AHCPU500-EN

Delta AHCPU530-RS2 – AH500 PLC CPU, 256K Steps and Two Serial Ports

The Delta AHCPU530-RS2 is a standard CPU for the Delta AH500 modular PLC system. It provides 256K program steps, 65,536 data registers (D0–D65535) and two DB9 serial ports. A Mini USB port connects the CPU to a computer, and an SD card slot supports system backup and restore.

Rack and I/O capacity

Delta specifies a maximum of 4,352 physical I/O points, 68 modules and one main backplane plus seven expansion backplanes for the AHCPU530. These are the system’s expansion limits. When planning the cabinet, check the AH expansion modules, available slots on each rack and the capacity of the AH power supplies.

COM1, COM2 and serial communication

COM1 and COM2 can be configured for RS-232, RS-422 or RS-485. When connecting an HMI, drive or another PLC, match the port standard, DB9 pinout, station address and serial settings to the peer device. Check the Modbus RTU or Modbus ASCII settings against the protocol selected on that device.

Delta documents PLC Link configuration for standard AH500 CPUs in NWCONFIG within ISPSoft. On the AHCPU530-RS2, use COM1 for automatic serial data exchange through this function. Check the project for the COM port already used by an HMI or drive before assigning it.

ISPSoft, connection cable and backup

Open the PLC project in ISPSoft and check the rack and module layout in HWCONFIG. For a direct PC connection, use a Mini USB data cable and the COMMGR communication channel. See Appendix A of the manual for the USB driver and Delta PLC software for engineering tools.

AHCPU530-RS2, AHCPU530-EN and AHCPU531-RS2

The AHCPU530-EN has the same 256K-step capacity and provides a serial port alongside built-in 10/100 Mbit/s Ethernet. The AHCPU531-RS2 is an advanced CPU with two serial ports and 384K program steps. The AHCPU520-RS2 provides two serial ports and 128K program steps. For additional networking options, see AH communication modules.

Manual and PDF downloads

Delta AH500 Hardware and Operation Manual (PDF, English). See PDF pages 40–41 (printed 2-4–2-5) for CPU and rack capacity, pages 45–47 (2-9–2-11) for the front panel and ports, and page 474 (11-22) for the PLC Link COM1 requirement.

See the Delta AH PLC PDF files archive for other manuals in the range.

Editor’s Note

When buying a spare, check the side label for the full AHCPU530-RS2 part number and verify the firmware version.

Back up the program, HWCONFIG rack layout and COM1/COM2 settings before removing the original CPU.

Label the DB9 cables by port and test both serial ports on the bench.

If BUS FAULT lights up, check the rack connection, expansion cables and module layout in the project.

Check the restore setting before first power-up with an SD card installed. An older backup on the card can be loaded into the CPU at startup.