Delta AHCPU501-EN
Delta AHCPU501-EN AH500 PLC CPU with Ethernet
Delta AHCPU501-EN is an advanced Delta AH500 rack-based PLC CPU with 48K program steps. It supports up to 768 physical I/O points through I/O modules on a single main rack. It has built-in 10/100 Mbps Ethernet, one serial COM port, Mini USB and an SD card slot. Within the Delta AH PLC series, it suits single-rack machines that require Ethernet connectivity.
Manual and port layout
AHCPU501-EN model overview (PDF, English) · Printed page 1-2 of the AH500 Hardware & Operation Manual lists program capacity and I/O support.
EN front panel and ports (PDF, English) · Printed page 2-10 shows Ethernet, COM, Mini USB, the SD slot and status indicators.
Main rack and memory capacity
Delta specifies up to 12 modules on one main rack. The CPU provides data registers D0–D24575 and 1 MB of function block memory. When planning the rack, check the slot and power requirements of the digital I/O and analog I/O you select from the AH expansion module range.
When selecting an AH power supply, account for the 100–240 V AC input of the AHPS05-5A and the 24 V DC input of the AHPS15-5A.
Ethernet, serial communication and ISPSoft
The Ethernet port supports Modbus TCP. The single serial COM port supports RS-232, RS-422 and RS-485. Match the PLC’s IP address and subnet mask to the project for Ethernet. For the serial connection, check the pinout, baud rate and parity.
Use a Mini USB data cable or an Ethernet cable for programming. Select the PC connection in COMMGR. Once connected, use HWCONFIG in ISPSoft to verify the module order and I/O addresses. Setup information is in the Delta PLC software section.
Editor’s note
When buying a used CPU, read the full AHCPU501-EN code on the label and match the EN suffix to the order.
Inspect the rear rack connector, Ethernet jack and Mini USB port. Verify that any loose or damaged port can maintain a bench connection.
On a compatible rack, watch the RUN, ERROR and BUS FAULT indicators at startup. Read the CPU model and firmware in ISPSoft.
Before replacing a CPU in a machine, back up the program, rack configuration, IP address and serial port settings.
If the Ethernet link light comes on and ISPSoft stays offline, check the PC subnet and COMMGR profile before replacing the CPU.
Related models and accessories
The AHCPU500-EN supports the same 768 physical I/O points with 32K program steps. The AHCPU501-RS2 provides 48K steps and two serial COM ports. For projects that need an expansion rack, see the AHCPU510-EN, AHCPU511-EN and AHCPU521-EN. For rack and cable selection, see Delta PLC accessories.