Delta AH communication modules

Delta AH communication modules

Delta AH communication modules add Ethernet, serial communications or fieldbus connectivity to a Delta AH500 PLC system. AHRTU units are remote station heads that connect I/O modules in another part of the machine to the field network. To select a module, identify the other device’s protocol and check each device’s network role. The 11 models in this category are grouped below by function.

Ethernet communication modules

AH10EN-5A · Two-port RJ45 Ethernet module with Modbus TCP and EtherNet/IP. It supports EtherNet/IP Scanner and Adapter roles.

AH15EN-5A · Two-port RJ45 Ethernet module with Modbus TCP and IEC 60870-5-104. For SCADA projects using IEC 104, check the protocol settings in the model manual.

Serial communication modules

AH10SCM-5A · Two RS-485/RS-422 ports with a removable terminal block. Supports Modbus RTU/ASCII and UD Link. For a drive or measuring instrument on RS-485, see the guide to Modbus and RS-485.

AH15SCM-5A · Two RS-232 ports with DB9 connectors. Supports Modbus RTU/ASCII and UD Link. When moving an existing device, check the DB9 pinout and serial settings together.

DeviceNet, PROFIBUS DP and CANopen modules

AH10DNET-5A · DeviceNet Master/Slave module. Use DeviceNet Builder for the master scan list and I/O mapping.

AH10PFBM-5A · PROFIBUS DP Master. Use it to manage field stations from the AH500 system.

AH10PFBS-5A · PROFIBUS DP Slave. Adds the AH500 system as a station on an existing DP Master network. Check the GSD file and data length in the master project.

AH10COPM-5A · CANopen Master/Slave module. Set the role in ISPSoft HWCONFIG. Use CANopen Builder for node configuration and PDO mapping on the master network.

AHRTU remote I/O stations

AHRTU-DNET-5A · DeviceNet remote I/O station head.

AHRTU-PFBS-5A · PROFIBUS DP Slave remote I/O station head.

AHRTU-ETHN-5A · Two-port Ethernet remote I/O station head. Supports the EtherNet/IP Adapter role and Modbus TCP communications.

When planning a remote panel, select AH digital modules, AH analog modules and AH power supplies to suit the station’s backplane and power requirements.

Software and technical PDFs

For communication cards installed in the CPU rack, check the module and slot assignment in ISPSoft HWCONFIG. See COMMGR for PC communications and Delta PLC software for protocol-specific tools.

AH500 Hardware and Operation Manual (PDF, English) · Module specifications and wiring diagrams in sections 4.11 and 4.12.

AH500 Module Manual (PDF, English) · Protocol settings, I/O mapping and troubleshooting.

All Delta AH PLC PDF files

Editor’s Note

Before ordering a replacement, get the full model code from the label and a photo of the front connectors.

For PROFIBUS, match the PFBM or PFBS code to the required Master or Slave role.

Record the serial port mode, baud rate, parity and station address. On fieldbus networks, also check the node number and termination.

Before removing the old card, back up the ISPSoft project and any separate network configuration. Keep a record of each I/O area’s start address and length.

If the link LED is on and data is missing, check the other device’s role and monitor live I/O. This helps distinguish a physical connection issue from a mapping issue.