Delta UB-10-IO34C / DVPAETB-IO34C
Delta UB-10-IO34C / DVPAETB-IO34C — External Terminal for AH15PM-5A
Delta UB-10-IO34C / DVPAETB-IO34C is an HDC external terminal assembly that brings the inputs, pulse outputs and auxiliary connections of the AH15PM-5A motion-control module to field terminals. It belongs to the Delta AH external terminals range and provides accessible panel wiring for the module’s CN1 connection within Delta AH PLC series applications.
AH15PM-5A, cable and terminal connection
The manufacturer cable guide shows AH15PM-5A CN1 external I/O port → UC-ET010-15B → UB-10-IO34C. UC-ET010-15B is a 1 m cable with female MDR50 connectors at both ends. Relevant hardware documents also show it alongside the DVPACAB7E10 code.
The catalogue identifies AH15PM-5A as a 4-axis pulse-type motion-control module. The module determines axis and pulse capabilities; IO34C organises its field connections. Compare other cables under Delta AH I/O cables.
Technical and mechanical information
| Item | UB-10-IO34C / DVPAETB-IO34C |
|---|---|
| Compatible motion module | AH15PM-5A |
| Connection port | CN1 external I/O |
| Connector arrangement | HDC / MDR50 |
| Cable option | UC-ET010-15B / DVPACAB7E10, 1 m |
| Mounting | DIN-rail base |
| Width × depth × height | 157 × 87 × 50.8 mm |
Signal groups on the terminal assembly
| Marking group | Function in the AH15PM-5A connection |
|---|---|
| Y0.0± … Y0.7± | Differential pulse-output pairs |
| Y0.8 … Y0.11 / COM | Auxiliary outputs and common terminal |
| X0… / X1… | Input signals; check the function against module settings |
| 24V / 24G | Supply connections |
| FE | Functional-earth connection |
| N/C | Unassigned terminal |
The table groups the AH15PM-5A terminal arrangement on page 3-97 of the manufacturer hardware manual. Read the equipment markings together with the detailed drawing for the complete terminal order. Differential “+” and “−” connections, 24G and FE serve different functions.
Selection differences from IO24C and IO16C
| Module | Cable | External terminal |
|---|---|---|
| AH15PM-5A | UC-ET010-15B | UB-10-IO34C / DVPAETB-IO34C |
| AH10PM-5A | UC-ET010-15B | UB-10-IO24C / DVPAETB-IO24C |
| AH04HC-5A / AH20MC-5A | UC-ET010-13B | UB-10-IO16C / DVPAETB-IO16C |
IO24C and IO34C have different terminal arrangements. Sharing a 50-pin cable does not remove the terminal-selection distinction between AH10PM-5A and AH15PM-5A. The IO16C group instead uses the 36-pin connection shown with DVPACAB7D10 / UC-ET010-13B.
Editor’s Note
Do not distinguish IO24C from IO34C by appearance alone. Their dimensions may be similar and they can share the same cable family. Confirm AH15PM-5A on the motion-module label and IO34C on the terminal assembly.
Inspect the HDC connector, retaining screws, terminals and rail clip on a used assembly. Examine corrosion, cracked plastic or strained cable entries closely. Release connector locks correctly rather than pulling the cable to disconnect it.
Switch off power and disconnect the cable and field wiring before continuity checks. Check contact-to-terminal paths and adjacent terminals for shorts against the diagram. Never apply an improvised supply to pulse terminals marked “+” and “−”.
If a servo does not move, check pulse generation, output mode, drive input selection and the cable before blaming the terminal assembly. If faults appear only at higher speeds, investigate signal quality and cable routing as well.
For limit, reference or other input checks, compare the monitored PLC bit with the actual signal at the terminal. Verify input commons and power before relying on the displayed value. Photograph the existing terminal order before making changes.
Begin testing under conditions that prevent unexpected machine movement. Measure pulse outputs with suitable equipment within the connected module’s electrical limits. After terminal repair, verify each input and output used by the application.
PDF and related topics
Use the Delta PLC accessories PDF and software files page for wiring and installation documents. Further documentation is available under Delta PLC and HMI manuals and Delta user manuals.
Review system components under Delta AH500 and AH Motion backplanes. Confirm rack and controller selection against their own compatibility tables.
Navigation: UB-10-IO34C / DVPAETB-IO34C main page · Delta PLC accessories · Delta PLC models · Used Delta products
External references
Delta AH Series Catalogue — Accessory Selection, 34–35 · Delta AH500 Hardware Manual — 3-93 / 3-97 · Delta PLC/HMI Cable Selection Guide — 2-25–26, Figure 17