Delta DVPACAB7D10

Delta DVPACAB7D10 — 1 m, 36-Pin HDC I/O Cable

Delta DVPACAB7D10 is a 1-metre, 36-pin I/O connection cable for the AH system. Within the Delta AH I/O cables range, it connects the field I/O of suitable counter and motion-control modules to an external terminal. Select the cable together with the module and terminal codes in the Delta AH PLC series.

Documented reference to UC-ET010-13B

The AH Motion hardware manual uses the designation UC-ET010-13B (DVPACAB7D10). The cable selection guide shows UC-ET010-13B with female MDR36–female MDR36 connections. When encountering the HDC designation, also check contact count and both connector ends.

Technical information

Item DVPACAB7D10
Length1 m
Contact count36
Connector familyHDC / MDR36
Code shown alongside it in the manualUC-ET010-13B
FunctionConnecting the module’s local I/O port to an external terminal

Module and terminal combinations

Connected module Function External terminal
AH04HC-5A High-speed counter UB-10-IO16C / DVPAETB-IO16C
AH20MC-5A DMCNET motion control UB-10-IO16C / DVPAETB-IO16C
AH10EMC-5A EtherCAT motion controller UB-10-IO22C / DVPAETB-IO22C

IO16C and IO22C have different terminal arrangements. Use of the same cable family does not make the terminal assemblies interchangeable. For AH10EMC-5A, the guide specifies the CN1 external I/O port. Follow the port and terminal diagram for the actual equipment.

DVPACAB7D10 completes the local I/O connection. Select the connected controller’s DMCNET or EtherCAT network cable separately. Axis count, counting frequency and output-current ratings belong to the relevant equipment rather than the cable alone.

Differences from DVPACAB7E10 and DB37 cables

DVPACAB7E10 and its documented reference UC-ET010-15B have 50-pin connections and are specified for AH10PM-5A and AH15PM-5A applications. Keep these separate from the 36-pin arrangement of DVPACAB7D10.

DVPACAB7C10 and UC-ET010-33B are DB37 I/O cables. Connector format, contact count and supported modules differ, so select using the complete ordering code.

Editor’s Note

Read D10 and E10 carefully. Both may be one metre long, but one has 36 contacts and the other has 50. Before ordering, obtain photographs showing the module label and both ends of the existing cable.

Check the terminal code as carefully as the cable code. Keep IO16C for AH04HC or AH20MC separate from IO22C for AH10EMC. Record existing terminal labels and wiring order before transferring field connections.

Inspect the connector latches, contacts and cable entries. A broken latch can cause intermittent contact under vibration. Measure the route and reasonable service clearance instead of stretching a one-metre cable to reach.

Switch off power and disconnect both ends before measurement. Check continuity and unintended shorts between adjacent contacts using the correct connector view. Do not treat the 36 contacts as 36 independent inputs.

In a counter application, continuity alone is insufficient. Apply a suitable test signal and compare incoming pulses with the count reported by the module. If counts are lost at higher speeds, investigate signal level, common connections and routing alongside the cable.

Do not judge a used cable by appearance alone. With power off and both ends disconnected, gently move the cable entries while checking for intermittent breaks. Follow with an operating test using suitable equipment, preventing machine movement during output checks.

PDF and related topics

Use the Delta PLC accessories PDF and software files page for wiring and installation documents. Further documentation is available under Delta PLC and HMI manuals and Delta user manuals.

For system components, review Delta AH500, AH Motion backplanes and AH external terminals.

Navigation: DVPACAB7D10 main page · Delta PLC accessories · Delta PLC models · Used Delta products

External references

Delta AH500 Operation Manual — DVPACAB7D10, 2-84 · Delta AH Motion Hardware Manual — 3-43 / 4-61–62 · Delta PLC/HMI Cable Selection Guide — 2-25–26 / 2-37