Delta DVPACAB7C10

Delta DVPACAB7C10 1-Metre DB37 I/O Connection Cable

Delta DVPACAB7C10 is a 1-metre DB37 cable connecting compatible AH I/O modules to external terminal boards. The manufacturer's manual identifies it alongside UC-ET010-33B. Both ends have 37-pin male DB37 connectors.

It belongs to the Delta AH I/O cables group. Verify the complete module model and terminal board together with the cable code.

Input and output module combinations

Input connection: AH32AM10N-5B to UB-10-ID32B / DVPAETB-ID32B.

NPN output connection: AH32AN02T-5B with UB-10-OR32A / DVPAETB-OR32A or UB-10-OT32B / DVPAETB-OT32B.

PNP output connection: AH32AN02P-5B with UB-10-OR32B / DVPAETB-OR32B or UB-10-OT32B / DVPAETB-OT32B.

Follow the relevant drawings for relay terminal boards and transistor output terminals. Include the module's T/P output type and -5B suffix in the ordering information.

DB37 connection and pin checks

37 pins do not represent 37 independent I/O channels. Read channel, common and supply assignments from the actual module's pin table. Matching DB37 bodies do not establish identical signal arrangements.

Distinguish the male plug's contact-face view from its cable-side view. Follow the manufacturer's viewing direction when reading pin numbers, and identify conductors by assignment rather than colour alone.

Disconnect the PLC and external I/O supplies before connecting or removing the cable. Align the plug, tighten fixing screws evenly and leave cable entries free of tension.

Differences from other DVPACAB7 cables

DVPACAB7A10 and DVPACAB7B10 appear as MIL-connector I/O cables in the manufacturer's table. Select DVPACAB7C10 by its DB37 arrangement.

DVPACAB7D10 and DVPACAB7E10 serve the I/O connections of different motion control modules. Compare both connectors and the module-to-terminal combination when selecting within this cable group.

Editor's Note

Record both ends before removing an older cable. Photograph the module label, terminal board and cable connectors. This reduces ordering mistakes, particularly those involving the -5B suffix.

Inspect male DB37 pins from an angle. A pin may be bent sideways or pushed back. Do not use the fixing screws to force a reluctant plug into place; establish correct alignment first.

Disconnect both devices before measuring the cable. Check continuity and shorts between neighbouring pins. An interrupted reading when gently flexing a connector entry suggests conductor or internal contact damage.

Check shared connections when several channels disappear together. A loose DB37 plug, terminal supply or common connection may affect a group of channels. Inspect these points before replacing the cable.

An output LED does not verify the entire field connection. Check relay-board power and the selected output arrangement against its diagram. Changing the cable does not correct an NPN/PNP mismatch.

Begin with one channel. Secure the machine and verify a known input in the PLC first. Establish what the load will do before testing an output, then check remaining channels in sequence.

PDF wiring drawings

Use our Delta PLC accessories PDF and software files page for documentation. Consult the UC-ET010-33B (DVPACAB7C10) identification in the AH Motion – Hardware Manual, together with the Section 2.4 combinations and Section 2.5, Figure 6 in the Delta PLC/HMI Cable Selection Guide.

Related subjects

See Delta AH PLC series and AH expansion modules for system selection, and AH external terminals and Delta PLC accessories for connection products.

Navigation: Used Delta products | Delta PLC models | PLC accessories | AH I/O cables | PDF and software files

External references

Delta AH Motion Hardware Manual, archive copy of the manufacturer document | Delta PLC/HMI Cable Selection Guide