Delta UB-10-OR32A / DVPAETB-OR32A

Delta UB-10-OR32A / DVPAETB-OR32A 32-Point Relay Terminal Module

Delta UB-10-OR32A, also identified as DVPAETB-OR32A, is a 32-point relay output terminal module for the AH32AN02T-5B NPN/sinking transistor output module. In a Delta AH PLC system, it receives output commands through a DB37 connection and provides relay contacts for switching field loads.

This Delta PLC accessory provides the field connection and relay interface. It does not add another set of PLC output addresses; addressing follows the connected AH output module.

Specifications and connection

Output arrangement: 32 relay outputs, a DB37 interface and screw terminals for field wiring. The Delta AH catalogue specifies 240 V AC / 24 V DC, 2 A. This is not an unconditional combined-current allowance for every channel; load inrush, switching frequency and current through the shared terminals require separate consideration.

Power supply: Apply an external 24 V DC supply to +24V and GND on the relay board. Distinguish this supply from the circuit switched by the contacts; connect the appropriate load voltage to the common terminals according to the manufacturer's diagram.

Connection cable: UC-ET010-33B, also listed as DVPACAB7C10 in the hardware manual, is a 1 m I/O cable with male DB37 connectors at both ends. Use the module–cable–terminal combinations shown under AH I/O cables when selecting accessories.

Mounting: The manufacturer's drawing gives dimensions of 215 × 87 × 39.4 mm. The assembly has DIN rail clips and base securing screws; allow additional enclosure space for the cable connector and field conductors.

Common terminals and AH output addressing

The outputs have eight common-terminal groups, C0–C7, with four outputs per common. The first row contains C0: Y0–Y3, C1: Y4–Y7, C2: Y10–Y13 and C3: Y14–Y17. The second contains C4: Y20–Y23, C5: Y24–Y27, C6: Y30–Y33 and C7: Y34–Y37.

Check the board labels against AH addressing: The manual's AH equivalent uses Y0.0–Y0.15 for the first 16 outputs and Y1.0–Y1.15 for the next 16. For example, board label Y10 corresponds to Y0.8, while Y20 corresponds to Y1.0. These are the manual's mapping examples; confirm the actual starting address in the project's module configuration.

Related terminals and model differences

UB-10-OR32B / DVPAETB-OR32B is the 32-relay option for the AH32AN02P-5B PNP/sourcing module. The module's NPN or PNP output arrangement determines whether OR32A or OR32B is selected.

UB-10-OT32B / DVPAETB-OT32B provides transistor output connections for the same DB37 module family. UB-10-OR16A / DVPAETB-OR16A and UB-10-OR16B / DVPAETB-OR16B are 16-relay terminals with MIL connections and different cable/module combinations.

UB-10-ID32B / DVPAETB-ID32B is the terminal for the AH32AM10N-5B digital input module. A similar DB37 connector does not give an input terminal the function of a relay output board.

Editor's Note

A lit PLC output LED does not establish that the relay board has power. Start by measuring +24V to GND on the board, then check the cable and module combination; this gives the fault investigation a clear starting point.

A relay click does not prove that its contact works properly under load. Test each channel with a suitable safe test load, and investigate intermittent switching or an unusually large contact voltage drop.

A loose common terminal can affect four outputs together. When an entire group stops working, check its supply, terminal and conductor before replacing the PLC output module.

Use load-appropriate suppression for contactors, solenoids and other inductive loads. Do not apply a DC coil's diode arrangement to an AC load; select protection for the actual voltage and the load manufacturer's recommendations.

Avoid using these relays for fast pulse generation or frequent switching. Do not parallel contacts to increase their current capability; use an appropriately rated interposing relay or contactor for heavier loads.

On used equipment, inspect DB37 pins, terminal threads, cracked solder joints and heat damage. Isolate both board power and switched load supplies before disconnection, and record test results by channel and common-terminal group.

PDF documents, software and related topics

For manuals and wiring documents, visit Delta PLC accessories PDF and software files. Further information is available under AH external terminals, AH digital modules, AH expansion modules and DVP / AH I/O cables.

Navigation: Delta products + Delta PLC models.

External references

Delta AH catalogue (accessory selection and ordering information); Delta PLC/HMI Cable Selection Guide (2-5, 2-20 and 2-36); Delta AH Motion Hardware Manual (3-62, 3-77 and 4-78).