Delta UC-ET010-13B
Delta UC-ET010-13B 1-Metre AH I/O Connection Cable
Delta UC-ET010-13B is a 1-metre cable with female MDR36 connectors at both ends, connecting a compatible AH controller or module's I/O port to an external terminal. The catalogue classifies it in the HDC connection group. It belongs to Delta AH I/O cables and Delta PLC accessories.
Controller, cable and terminal matching
The manufacturer's selection tables pair AH04HC-5A and AH20MC-5A with the UB-10-IO16C external terminal through UC-ET010-13B. For AH08EMC-5A, AH10EMC-5A and AH20EMC-5A, the specified terminal is UB-10-IO22C.
The cable code alone is insufficient when selecting Delta AH external terminals. Use of the same cable with different devices does not make UB-10-IO16C and UB-10-IO22C interchangeable. Check the complete model and port designation on Delta AH motion controllers together with the terminal label.
MDR36 connector and pin functions
MDR36 identifies a 36-contact connector, not 36 independent I/O channels. Figure 12 in the cable guide provides separate pin tables for AH20MC-5A and AH10EMC-5A. Assess inputs, outputs, common connections and unused contacts according to the connected device's diagram.
Confirm the connector's contact-face viewing direction. Do not treat COM, C groups, S/S and X/Y signals as one universal pin assignment. Follow the actual device's wiring table when replacing the cable or repairing an end; physical connector fit does not verify signal compatibility.
Differences between 13B, 15B and 33B
UC-ET010-33B is a different I/O cable with male DB37 connectors at both ends. UC-ET010-15B has female MDR50 connectors at both ends; the connection between AH10PM-5A and UB-10-IO24C is an example. Equal one-metre length and the UC-ET010 prefix do not establish equivalence.
UC-ET010-13B carries the module's field I/O signals to the terminal. EtherCAT or DMCNET servo-network connections and program downloads from a computer use the device's separate port and the appropriate cable.
Installation, routing and software
1 metre is the cable's physical length. Allow for cable-duct bends, plug bodies and maintenance clearance when positioning the terminal. Avoid tension, engage the connector locking elements and support the cable so its weight does not load the port.
Delta AH Motion backplanes and AHBP07M2-5A concern module placement on the rack. Plan the external terminal cable route separately, from the controller's I/O port to the terminal assembly.
No software or firmware is installed in the cable. Configure I/O addresses and signal functions in the connected controller or module's project. Use Delta PMSoft for a motion-controller project according to the tools supported by the device model and firmware version.
Editor's Note
Check the 13B suffix when ordering. Do not select a cable marked 15B or 33B solely because it is one metre long. Compare the controller and external terminal labels at the same time.
Inspect a used cable's plug housings, latches and contacts. Do not force a connector with bent or recessed contacts into place. Route the cable so it does not pull the connected port sideways.
Disconnect power and remove the cable from both devices before continuity testing. Check the ends against the diagram while gently moving each cable entry; intermittent breaks may be missed by a stationary measurement.
If an entire input group fails, check more than the signal conductors. Verify the relevant common connections, S/S wiring and field supply against the device diagram. Common-terminal arrangements can differ between modules using the same connector.
Prevent machine movement safely during initial testing. Monitor inputs individually and test outputs under controlled conditions. Compare a suspect cable with a known-good compatible one, and complete verification by observing actual I/O operation as well as meter readings.
PDF and wiring documentation
Consult Delta PLC accessories files and Delta PLC and HMI manuals for wiring documents. The manufacturer's PLC/HMI cable guide lists device combinations on printed pages 2-25 and 2-26. The UC-ET010-13B connector drawing and pin tables are on page 2-37, Figure 12.
Related topics
Delta AH I/O cables · Delta AH external terminals · Delta UB-10-IO16C / DVPAETB-IO16C · Delta AH10EMC-5A · Delta UC-ET010-33B · Delta UC-ET010-15B
Return to Delta PLC accessories. Browse controllers in the Delta PLC category and available equipment under second-hand Delta products.
External references: Delta PLC/HMI Cable Selection Guide (archived manufacturer document) · Delta AH Series Catalogue