Delta AH08EMC-5A
Delta AH08EMC-5A | 8-Axis EtherCAT Motion Control CPU
The Delta AH08EMC-5A is a Delta AH Motion CPU that controls up to eight physical axes over EtherCAT. Delta specifies a minimum synchronization time of 0.5 ms at eight axes. Built-in program storage is 256K steps. Typical applications include coordinating compatible EtherCAT servo drives on packaging, assembly and multi-axis positioning equipment.
EtherCAT, Ethernet and Mini USB
The EtherCAT port connects the drives and devices on the motion network. The separate Ethernet port supports ISPSoft connections, Modbus TCP and EtherNet/IP adapter communications. The Mini USB port also supports program transfer. When planning cabinet wiring, check the roles of EtherCAT and Ethernet and the drive order on the network.
ISPSoft, COMMGR and axis mapping
Use ISPSoft and HWCONFIG to set up the CPU project and rack. Select the programming connection between the PC and the CPU in COMMGR. In ECAT Builder, verify each drive’s exact model and station address. Then map each logical axis to its EtherCAT station. Record the axis number and drive station address together in the project so maintenance staff can identify the correct axis.
Motion backplane and power supply
The AH08EMC-5A installs in the CPU slot of an AH Motion backplane. The AHBP03M2-5A, AHBP05M2-5A and AHBP07M2-5A provide three, five and seven additional module slots, respectively. Select the AHPS05-5A (100–240 V AC) or AHPS15-5A (24 V DC) power supply to suit the cabinet supply. Check the rack and CPU compatibility table for the intended expansion modules.
Manuals and PDF downloads
AH Motion Controller Operation Manual — PDF · English · 2023-05-10 · 333 pages. See printed page 1-8 for axis specifications, chapters 3 and 4 for ISPSoft connection and hardware configuration, and page 7-7 for EtherCAT station-to-axis assignment.
AH Motion Hardware Manual — PDF · English · 2016-07-15. See section 3.2.3 for ports and chapter 2 for rack and module selection. More series documentation is available in the Delta AH PLC PDF library.
Editor's Note
When buying a used controller, check the AH08EMC-5A part number, the rear backplane connector and the latch slots on both RJ45 ports.
Before replacing the CPU, back up the ISPSoft project and EtherCAT configuration. Record the physical drive order, station addresses and axis assignments.
If ISPSoft connects to the CPU and the drives are missing, check the EtherCAT port, drive chain and device list in ECAT Builder.
If a drive appears on the network and the axis receives no command, check the axis-to-station mapping, drive ready status and fault log first.
In a safe test setup, verify each axis individually at low speed. Confirm direction, homing and travel limits before testing coordinated motion.
Related topics
For higher EtherCAT axis counts, see the 16-axis AH10EMC-5A and 32-axis AH20EMC-5A. The AH05PM-5A page covers pulse-train motion and the AH20MC-5A page covers DMCNET motion.
More from OtomasyonAVM
Delta AH PLC series ·
Delta PLC software ·
Delta PLC ·
Used Delta equipment
External references
Delta Electronics AH Motion product information ·
Delta AH Motion operation manual — distributor copy