The Delta AH10EMC-5A is an AH Motion controller in the Delta AH series that supports 16 physical axes. Its built-in 100 Mbps EtherCAT master port controls compatible servo drives and field devices. Delta specifies a built-in motion program capacity of 256K steps.
Typical uses include coordinating axes in multi-axis packaging, cutting, feeding and positioning machinery. PLCopen motion function blocks support functions such as linear and circular interpolation. When sizing the system, check the number of physical servo axes and the full order code of each drive.
EtherCAT, backplane and field wiring
EtherCAT and Ethernet ports Connect the servo network to the front port marked EtherCAT. Use the separate Ethernet port or Mini USB to transfer and monitor programs from a computer. Choose the drive network cable from the Delta EtherCAT cable range.
Backplane selection When using the controller as the CPU, install it in the CPU position of an AH Motion M2 backplane. Compare slot counts on the AHBP03M2-5A and AHBP07M2-5A. Match the total rack power requirements to the capacity of the AH power supply.
CN1 field I/O The front CN1 connector carries local field signals. Delta specifies the UC-ET010-13B cable with the UB-10-IO22C terminal for this model. See Delta external terminals for terminal selection.
Programming and PDF manual
ISPSoft and COMMGR Open the project in ISPSoft and check the backplane and module layout in HWCONFIG. Connect through COMMGR, then compare the EtherCAT device order and axis assignments against the project.
PDF manual AH Motion Hardware Manual (English, 2016). See section 3.2.2 for motion specifications and 3.2.3 for communication ports. See Delta AH PLC PDF Files for further series documentation.
Editor’s Note
On a used controller, check the full AH10EMC-5A order code and inspect the EtherCAT, Ethernet and CN1 connectors.
Before removing a unit from a machine, back up the ISPSoft project and record drive order, axis assignments and firmware versions.
On the bench, connect online to the CPU first. Then check that a compatible EtherCAT drive appears on the network under the expected axis.
If a drive does not appear, check that the cable is in the EtherCAT port and that the physical drive order matches the project.
For the first move, use a safe test setup and run one axis at low speed. Verify direction, homing and limit inputs individually.
Related Topics
Model selection The AH08EMC-5A supports 8 physical axes and the AH20EMC-5A supports 32. For an existing DMCNET system, see the AH20MC-5A network and hardware details. For stand-alone auxiliary panel control, see the Derell DLC-R1210-2I-R-A smart relay.
AH expansion modules · Delta PLC software · Delta PLC accessory files · Delta PLC · Second-hand Delta products
External References