Delta external terminals
Delta External Terminals — Input, Transistor-Output and Relay Interfaces
Delta external terminals carry a compatible PLC I/O module’s multipin connection to field-wiring terminals inside the cabinet. The basic options in this group provide 32-input wiring, 32-transistor-output wiring and a 16-relay output interface. Within Delta PLC accessories, assess the complete module → cable → terminal → load connection.
OR types contain relay interfaces, so the whole group should not be treated as passive wiring distribution. Terminal selection determines how the existing module’s signals reach field equipment. Adding an external terminal does not automatically increase CPU I/O addresses; no PLC program is downloaded to the terminal board.
Three basic terminal options
The input terminal under UB-10-ID32A / DVPAETB-ID32A provides field wiring for 32 input points. A DVP example is the DVP32SM11N input module. Verify signal voltage, current and common-terminal arrangement against the connected module’s specifications.
The terminal under UB-10-OT32A / DVPAETB-OT32A carries 32 transistor outputs to field wiring. It is among the documented connection options for DVP32SN11TN. Using an OT terminal does not increase the connected module’s permitted output current or voltage.
UB-10-OR16A / DVPAETB-OR16A is a 16-relay output interface. The manufacturer’s drawing uses two OR16A units to interface all 32 DVP32SN11TN outputs through relays. Select the load supply, commons and suppression separately for the equipment switched by the relay contacts.
Match the UB-10 and DVPAETB names grouped on these pages to the actual product label and complete board code. Compare document edition, connector and pin diagram during replacement; similar names alone do not establish compatibility across all revisions.
Module, cable and terminal matching
For 40-pin → 40-pin connections, UC-ET010-24A and shielded UC-ET010-24B are 1 m options. The manufacturer’s guide shows them with ID32A and OT32A terminals. Shielded alternatives are UC-ET020-24B at 2 m and UC-ET030-24B at 3 m.
For a 40-pin → two 20-pin split connection, UC-ET010-24C and shielded UC-ET010-24D are 1 m options. Shielded UC-ET020-24D is 2 m and UC-ET030-24D is 3 m. This split arrangement is shown between DVP32SN11TN and two OR16A terminals.
When selecting Delta DVP / AH I/O cables, check pin order, commons, latch orientation and shield connection as well as pin count. For a system using Delta AH I/O cables, record the complete AH module suffix. Use its specific manufacturer drawing before substituting a cable based on connector appearance.
Power, loads and cabinet installation
Connect the OR16A and OT32A auxiliary-supply terminals according to their diagrams; the manufacturer specifies a 24 V DC auxiliary supply for these output terminals. Distinguish +24 V/GND from relay-load commons. Read ID32A input-signal limits from the connected input module.
For relay interfaces, check individual contact loads separately from the common-group total. Contactor and valve coils require suitable suppression. When reviewing Delta DVP power supplies, calculate terminal auxiliary demand separately from field-load current. Check DIN-rail clips, terminal tightness and cable clearance around connectors during installation.
Distinguish DVP and AH applications
Delta AH external terminals includes additional options for input, relay, transistor and motion-module connections. -5B/-5C module distinctions, NPN/PNP outputs and A/B terminal suffixes can affect selection. Do not apply the DVP example to every AH card; use the module-specific pairing diagram.
Editor’s Note
Identify the separate jobs of the PLC module, connecting cable and terminal board first. Keep photographs of the nameplate, board code and both cable ends together. A description such as “32-point terminal” is usually insufficient for selecting the right part.
For a missing input, work from the sensor through field terminal, common, cable and PLC input. If several channels disappear together, inspect shared power and connectors before treating every channel as faulty.
A clicking relay does not establish healthy contacts under load. Have each OR16A channel checked with a suitable, limited test load. Distinguish burnt or welded contacts from a broken common connection.
Keep the PLC output-current limit in mind when using OT32A. Larger field terminals do not make the output transistor more powerful. Compare the load’s voltage and current requirements with the connected module’s ratings.
Measure cable continuity with both ends disconnected from equipment and power removed. Inspect bent IDC pins, reversed connectors and ribbon cable crushed beneath covers. Avoid applying arbitrary test voltages to connected electronic boards.
During repair, inspect terminal solder joints, common tracks, corrosion and overheating. Replacement relays must match coil voltage, contact arrangement and pin layout. Afterwards, verify the complete connection channel by channel, not just the initially suspect point.
PDFs and technical documents
Use Delta PLC accessories files. Sections 2.1, 2.4 and 2.5 of Delta PLC/HMI Cable Selection Guide, 15 August 2019 cover module, cable and pin matching. Explore Delta PLC and HMI manuals for other document groups.
Related topics and navigation
Use the Delta PLC family to review CPUs and I/O modules, and Delta PLC accessories for associated connection and power hardware. Browse used Delta equipment for listed units. Confirm whether the terminal, connecting cable and removable blocks are included in a purchase.
External references
Delta UB-10-ID32A / OR16A / OT32A manufacturer instruction sheet · Delta PLC/HMI Cable Selection Guide — English, 15 August 2019, DigiKey-hosted copy · Delta AH manufacturer catalogue — English, Dimotor archive copy