Delta UB-10-IO24C / DVPAETB-IO24C

Delta UB-10-IO24C / DVPAETB-IO24C AH10PM External I/O Terminal

Delta UB-10-IO24C / DVPAETB-IO24C is an external terminal board bringing AH10PM-5A motion-module I/O signals to field terminals. The manufacturer uses both codes as alternative designations. It belongs to Delta AH external terminals and Delta PLC accessories. The connected module performs pulse generation and motion control.

AH10PM-5A and MDR50 cable connection

The specified combination is AH10PM-5A → UC-ET010-15B → UB-10-IO24C. UC-ET010-15B is a 1-metre cable with female MDR50 connectors at both ends. Legacy documents also list DVPACAB7E10 for this connection. Check cable and terminal labels together with the module's complete order code.

When examining AH temperature / motion modules within Delta AH PLC series, preserve the function of the connected port. This connection runs between the module's I/O port and field terminal; it is not a CPU expansion-rack link or a servo communication network.

Differential signals and common connections

The drawing includes differential input pairs such as X0.0+ / X0.0−, differential output pairs such as Y0.0+ / Y0.0−, and separate digital I/O connections. The “+” and “−” markings belong to the relevant signal pair. Do not wire them as general supply positive and negative; compare the module and servo-drive input circuits.

Read C0–C3, S/S, 24V, 24G, FE and N/C assignments from the manufacturer's diagram. Output commons, input common connections, supply reference and functional earth serve different purposes. Do not use N/C terminals as extra signals or jumper points.

The AH10PM-5A catalogue specifies 1 MHz outputs for four axes and 200 kHz for two axes. These are motion-module capabilities. Verify the selected pulse/direction mode, drive input type and cable route when planning the terminal connection.

Differences from IO16C and IO34C

UB-10-IO16C / DVPAETB-IO16C is used with AH04HC-5A and AH20MC-5A, using the UC-ET010-13B or legacy DVPACAB7D10 cable group. Its MDR36 arrangement differs from IO24C's MDR50 connection.

The manufacturer's detailed connection table pairs UB-10-IO34C / DVPAETB-IO34C with AH15PM-5A. Its use of the same UC-ET010-15B cable as IO24C does not establish an identical terminal arrangement. Compare pin and terminal functions individually when changing models.

Installation, wiring and programming

The manufacturer's drawing specifies dimensions of 157 × 87 × 50.8 mm for IO24C. Check the DIN-rail clip and fixing components. Allow cabinet space for terminal access and MDR50 plug bends.

Review cable selection under Delta AH I/O cables and Delta DVP / AH I/O cables. Preserve differential-pair assignments to the drive, separate signal wiring appropriately from motor power cables, and complete shield/earth connections according to the device diagrams.

No program or firmware is loaded into the terminal. Review Delta PMSoft documentation for the motion-module project and Delta ISPSoft documentation for AH CPU configuration according to the model and version used. Replacing a board under Delta external terminals does not automatically change I/O addresses or motion parameters.

Editor's Note

Do not interpret the number in IO24C as a relay-output count. Verify the AH10PM-5A module first, then check the complete cable and terminal labels.

Label wires by terminal designation before removal. Record “+ / −” pairs together rather than relying only on wire colour. Incorrect assignments can prevent axis movement or cause unexpected behaviour.

Inspect a used board for bent connector contacts, loose terminals, corrosion and cracked solder joints. Disconnect power and remove module/drive connections before continuity testing; do not measure through connected electronics.

A multimeter alone cannot rule out a pulse-signal fault. Use suitable differential or isolated measurement methods to compare signals at the module, terminal and drive. Do not attach a grounded oscilloscope probe arbitrarily to a differential signal conductor.

Keep initial machine movement controlled and verify direction, limit and home inputs. If a fault appears only while motors run, also inspect cable routing, reference connections and shielding.

PDF and wiring documentation

Consult Delta PLC accessories files and Delta PLC and HMI manuals for relevant documents. The AH Motion Controller Hardware Manual lists alternative codes, while the AH500 Hardware Manual covers module and terminal wiring. The PLC/HMI cable guide shows device matching on 2-25, the cable drawing on 2-39 / Figure 15 and IO24C terminal layout on 2-40 / Figure 16.

Related topics

Delta AH10PM-5A · Delta UC-ET010-15B · Delta DVPACAB7E10 · Delta UB-10-IO16C / DVPAETB-IO16C · Delta UB-10-IO34C / DVPAETB-IO34C · Delta AH harici terminaller

Return to Delta PLC accessories. Browse controllers in the Delta PLC category and available equipment under second-hand Delta products.

External references: Delta AH Series Catalogue · Delta PLC/HMI Cable Selection Guide · Delta AH500 Hardware Manual (archived manufacturer document)