Delta AH04TC-5A
Delta AH04TC-5A – 4-Channel Thermocouple Module
The Delta AH04TC-5A is a four-channel thermocouple temperature input module for the Delta AH PLC system. It supports types J, K, R, S, T, E and N and a ±150 mV voltage input. Temperature resolution is 0.1 °C / 0.1 °F, conversion takes 200 ms per channel, and internal power consumption is 1.5 W.
Typical applications include PLC monitoring of extruder zones, moulds, ovens and heating stations. The inputs are marked CH0–CH3. The AH08TC-5A provides eight thermocouple inputs. For resistive sensors such as Pt100 or Pt1000, consider the AH04PT-5A.
Input ranges and wiring
Module temperature input ranges J −100 to +1150 °C, K −100 to +1350 °C, R and S 0 to +1750 °C, T −150 to +390 °C, E −150 to +980 °C, N −150 to +1280 °C. Check the probe’s own operating range and sheath temperature limit.
For CH0 wiring, connect the positive thermocouple lead to I0+ and the negative lead to I0−. Use an extension or compensation cable matched to the sensor type, including type K, and route the signal cable away from power wiring. The module provides cold-junction compensation and open-sensor detection.
Software and addressing Check the module slot, channel type and start address in ISPSoft HWCONFIG. Four inputs occupy eight data registers. Check COMMGR settings when connecting to the CPU online.
PDF manual Delta AH500 Hardware and Operation Manual (English). See section 4.10.3 for AH04TC-5A wiring and 5.4.3 for data registers. Further series documentation is available under Delta AH PLC PDF Files.
Editor’s Note
When buying a second-hand module, check the full model code and confirm that the removable JIS terminal block is included.
Allow the 30-minute warm-up specified by Delta before taking measurements.
On the bench, apply the same two reference values to all four channels with a suitable thermocouple calibrator and compare the readings.
If the temperature reading is off, check the channel’s sensor setting, lead polarity and compensation cable first.
If one channel is suspect, compare it with the others using a known-good probe and check that open-sensor diagnostics work.
Related Topics
Thermocouple types · Pt100 vs thermocouple · What is an analog input? · Second-hand temperature sensors and probes
Related modules and application options The AH08TC-5A provides eight thermocouple inputs, the AH04PT-5A four RTD inputs, and the AH08PTG-5A eight RTD inputs. For stand-alone panel temperature control, see the Derell DESP-99-RS-A.
AH temperature and motion modules · AH expansion modules · AH analog modules · Delta PLC software · Delta PLC · Second-hand Delta products