Delta AH10PM-5A

Delta AH10PM-5A pulse-train motion control module

The Delta AH10PM-5A is a six-axis motion control module that sends pulse-train position commands to drives in a Delta AH500 system. It provides four axes at up to 1 MHz and two axes at up to 200 kHz. It belongs to the AH temperature and motion module family.

For feeding and positioning applications, the module supports two- to six-axis linear interpolation, two-axis circular interpolation and three-axis helical interpolation.

Specifications and connections

The first four axes use differential pulse outputs. Axes five and six use open-collector pulse outputs. Match the output mode to the drive input using pulse/direction, CW/CCW or A/B phase.

Program capacity is 64K steps, internal power consumption is 2.7 W, and dimensions are 110 × 35 × 103 mm (H × W × D). The front panel has a RUN/STOP switch and RUN, ERROR and Ethernet status indicators.

The HDC field connection uses the UC-ET010-15B or DVPACAB7E10 extension cable and the UB-10-IO24C / DVPAETB-IO24C terminal block. See AH I/O cables and AH external terminals for other models.

PMSoft programming

Edit the motion project in Delta PMSoft. Connect the PC via Mini USB or Ethernet. Use ISPSoft for the host AH500 CPU project and COMMGR for PC communication.

The project configuration defines the registers exchanged between the CPU and the motion module. Back up the axis assignments, pulse mode and scaling parameters with the PMSoft project. See Delta PLC software and Delta PLC programming cables for related resources.

Manuals and technical PDFs

Delta AH500 Hardware and Operation Manual (PDF, English) · Section 4.13.4 covers HDC wiring.

Delta AH500 Programming Manual (PDF, English) · AH500 instructions and model error codes in section 7.1.4.

Delta AH Series Catalog (PDF, English) · Axis counts, dimensions and accessories.

All Delta AH PLC PDF files

Editor’s Note

When buying a used unit, check the AH10PM-5A nameplate and inspect the front HDC socket and rear connector.

If the listing includes the UB-10-IO24C block and cable, ask for a photo of each label.

Before replacing the module, back up the motion program, axis parameters and host CPU data exchange settings.

Check the drive pulse input type for each axis. Include the 200 kHz limit for axes five and six when calculating electronic gearing.

On the bench, check the RUN/ERROR indicators, PMSoft connectivity and the operation of the outputs you intend to use.

Related models and topics

AH05PM-5A two-axis pulse module · AH15PM-5A four-axis pulse module with LSP/LSN inputs · AH20MC-5A DMCNET motion module · AH10EMC-5A EtherCAT motion controller.

For pulse-input drive specifications, see Delta ASDA-A2 and the Derell DS2 200 W servo kit.

Delta AH PLC series · AH expansion modules · AH motion controllers · AH power supplies · Delta PLC · Delta Automation

Delta Electronics AH Series Catalog