Delta DVP ES2 / EX2 modules
Delta DVP ES2 / EX2 modules – Digital I/O expansion guide
Delta DVP ES2 / EX2 expansion modules connect to the right-side expansion bus of DVP-ES2 and DVP-EX2 PLC systems. XM reads field inputs, XN adds outputs, and XP combines inputs and outputs in one module. For models with outputs, R indicates relay and T transistor. Start by counting the extra inputs and outputs separately.
Digital module table · Analog, temperature and resolver · Addressing and software · PDFs and manuals
Digital expansion modules
DI means digital inputs and DO means digital outputs. Open the model page for technical details and use the PDFs for terminal drawings.
| Function | DI | DO | Input / Relay model | Transistor model |
|---|---|---|---|---|
| Input only | 8 | 0 | DVP08XM211N | – |
| Input only | 16 | 0 | DVP16XM211N | – |
| Output only | 0 | 8 | DVP08XN211R | DVP08XN211T |
| Output only | 0 | 16 | DVP16XN211R | DVP16XN211T |
| Output only | 0 | 24 | DVP24XN200R | DVP24XN200T |
| Mixed I/O | 4 | 4 | DVP08XP211R | DVP08XP211T |
| Mixed I/O | 8 | 8 | DVP16XP211R | DVP16XP211T |
| Mixed I/O | 16 | 8 | DVP24XP200R | DVP24XP200T |
| Mixed I/O | 16 | 16 | DVP32XP200R | DVP32XP200T |
Check the module supply against the full order code. In Delta’s instruction sheet, the listed 8-point 211 modules take power from the CPU bus. The 16-point 211 models take 24 V DC, and the 200 models in the table take 100–240 V AC module power. The digital inputs are rated for 24 V DC. Use each transistor model’s diagram to verify field load power.
Match the S/S common to the PNP/NPN circuit for inductive sensors and limit switches. For relay outputs, check contact load and switching frequency. For transistor outputs, check DC load voltage, polarity and current per common group. Use appropriate fusing and specified suppression for coil loads. A suitable flyback diode limits the voltage spike on a DC coil.
Three field examples · Use DVP08XM211N for eight extra sensors, DVP08XN211R for eight relay outputs, or DVP24XP200T for 16 inputs and eight transistor outputs. DVP24XN200T provides 24 outputs. The two 24-point modules serve different I/O requirements.
E2 modules for analog, temperature and resolver signals
An EX2 CPU has four built-in analog inputs and two analog outputs. When the channel count or signal type calls for expansion, see Delta DVP E2 modules. An analog input reads a sensor signal. An analog output sends a reference to a drive or controller.
| Model | Function |
|---|---|
| DVP04AD-E2 | 4 analog inputs |
| DVP02DA-E2 | 2 analog outputs |
| DVP04DA-E2 | 4 analog outputs |
| DVP06XA-E2 | 4 analog inputs + 2 analog outputs |
| DVP04PT-E2 | 4 RTD temperature inputs |
| DVP04TC-E2 | 4 thermocouple inputs |
| DVP10RC-E2 | Shaft angle measurement with a resolver |
For 0–10 V and 4–20 mA devices, check the channel mode and PLC scaling. For Pt100, check the RTD type and wiring. For a thermocouple, check sensor type and polarity. For shaft angle, match the resolver module to the sensor’s excitation and feedback specifications.
Addressing, WPLSoft, ISPSoft and programming cable
For example, the DVP32ES200R has 16 inputs at X0–X17 and 16 outputs at Y0–Y17. With a DVP16XP211R as the first digital expansion module, the eight added inputs occupy X20–X27 and the eight added outputs occupy Y20–Y27. X and Y use octal addresses. Track input and output ranges separately when adding more modules.
Delta’s ES2/EX2 manual specifies up to eight special I/O modules. The extreme digital configurations shown are 256 DI + 16 DO or 16 DI + 256 DO. Check the actual capacity against the CPU model, built-in I/O, module arrangement and power budget.
Use digital expansion points in the CPU’s ladder program. For special E2 modules, use the module’s CR table for channel modes, scaling, errors and measurements. If an existing project uses FROM/TO, compare module order and CR numbers. On supported ES2/EX2 CPUs, D1320–D1327 help identify special modules in connection order.
Use WPLSoft or ISPSoft for PLC programming. Set up ISPSoft serial communications through COMMGR. For COM1 RS-232 on a standard ES2/EX2 CPU, use UC-PRG020-12A with a USB-equipped PC or UC-MS020-01A with a physical serial port. Match the Delta PLC cable to the CPU port. On a Modbus RS-485 link, match ASCII or RTU mode with the connected device.
Editor’s Note
Inspect the label and terminals. When buying used, ask for photographs of the full model code, expansion connector and terminal cover.
Check three separate supplies. Mark the CPU supply, module supply and field load supply on the diagram.
Test outputs under load. With the Y LED on, check the relay contact or transistor output using a suitable test load. If a group fails, start with its common terminal.
Record the module order. Back up the project, I/O list and special module CR settings before replacement. Verify one physical input and one output against their addresses during the first test.
Test the analog reading at two points. Apply a suitable reference near the lower and upper ends. If readings move when a motor starts, check grounding, shielding and electromagnetic interference.
Internal references and PDFs