Delta DVP32XP200R

Delta DVP32XP200R – 16 Digital Inputs / 16 Relay Outputs Expansion Module

Delta DVP32XP200R is an expansion module providing 16 digital inputs and 16 relay outputs for DVP-ES2 and DVP-EX2 systems. Its main supply is 100–240 V AC and its inputs accept 24 V DC signals. It expands the host PLC; it is not a standalone programmable CPU.

Typical applications include additional sensors and control outputs on conveyors, packaging machines and auxiliary panels. It belongs to the Delta ES2/EX2 module range. Delta’s 2024 catalogue also lists this code in the ES3/ES3-TEC/EX3/ES2/EX2 digital module table. Check the selected CPU hardware manual and expansion limits before using it with another host family.

Technical specifications

I/O: 16 DI + 16 DO with mechanical relay outputs. Main power connects to L/N: 100–240 V AC, 50/60 Hz. The 2009 installation sheet specifies 25 VA consumption for DVP32XP200R and a 100 mA auxiliary +24 V DC output. Include all connected sensor loads in that auxiliary supply budget.

Inputs: 24 V DC, approximately 5 mA, with sinking or sourcing wiring. ON level >15 V DC; OFF level <5 V DC; input impedance 4.7 kΩ. OFF→ON response is 10 ms ±10% and ON→OFF response is 15 ms ±10%. For an inductive sensor or photoelectric sensor, match the NPN/PNP output type to the S/S common connection.

Relay outputs: the 2024 Module Manual specifies 10–250 V AC / 5–30 V DC, with a resistive load rating of 2 A per output and 5 A per COM. Add the currents of all outputs sharing a common. Response is approximately 10 ms and switching frequency is at most 1 Hz, also affected by the scan cycle. Relay contact life depends on load type and inrush current; the resistive rating must not be applied unchanged to inductive loads.

Installation: 35 mm DIN rail or screw mounting, removable terminals and channel LEDs. Body width is 145 mm, body height is 90 mm and weight is approximately 340 g. Allow for terminals, connection parts and wiring clearance using the complete dimensional drawing.

Power, commons and conflicting terminal drawings

L/N are the main AC supply terminals. Never apply mains voltage to X inputs. +24V/24G identify the auxiliary DC supply and S/S is the input common. A typical PNP sensor arrangement uses S/S=0 V; a typical NPN arrangement uses S/S=+24 V. Follow the matching manufacturer wiring diagram for supply and sensor commons.

The published drawings differ: the 2024 Module Manual, printed pages 2-8 and 2-18, shows C0: Y0–Y7; C1: Y10–Y17. The 2009 DIDO sheet, printed page 8, shows C0: Y0–Y3; C1: Y4–Y7; C2: Y10–Y17. These documents alone do not establish when any physical hardware change occurred. Use the markings on the actual unit and its matching diagram; do not interchange these drawings. Terminals marked NC are unused connections, not normally closed relay contacts.

Provide protective grounding and appropriate load circuit fuses. Implement emergency stop and other safety functions with the required safety hardware; ordinary PLC I/O alone is not a safety circuit.

Programming software and cable

No separate program is downloaded to DVP32XP200R. PLC programming takes place in the ES2/EX2 host using WPLSoft or ISPSoft, subject to CPU and software version support. Inputs and outputs are used as X/Y devices in the ladder diagram. X0–X17 and Y0–Y17 printed on the module are local channel labels; actual project addresses depend on the CPU and preceding expansion modules. DVP X/Y numbering is octal: 10 follows 7.

Standard ES2/EX2 programming connection: Delta’s 2019 cable guide, printed page 1-3, shows UC-PRG020-12A from a PC USB port to the CPU COM1 RS-232 port. A PC with RS-232 can use UC-MS020-01A; a USB–RS-232 adapter arrangement also requires matching pinout and drivers. Configure the COMMGR driver and COM port when connecting through ISPSoft. The Delta programming cable connects to the host, not to this module’s terminals. For another host family, follow that CPU’s port documentation.

Application limits and related topics

The input filter times require a suitable high-speed CPU input or counter module for fast encoder pulses. Relay outputs cannot provide pulse commands for a servo or stepper motor. Analog signals, Pt100 sensors and thermocouples require suitable additional modules. A PID control application needs separately selected measurement and output hardware.

Modbus/RS-485, Modbus RTU, Ethernet, EtherNet/IP and Modbus TCP or CANopen requirements are determined by the host CPU and communication hardware. DVP32XP200R does not add a communication port.

Related models and selection

DVP32XP200T: 16 inputs/16 transistor outputs. DVP24XP200R: 16 inputs/8 relay outputs. DVP24XN200R: 24 relay outputs. DVP16XP211R: 8 inputs/8 relay outputs. Compare I/O count, power supply and terminal layout together. For a new control system, Derell PLCs and smart relays may also be considered; they are not direct plug-compatible replacements for this Delta expansion module.

Editor’s Note

For a used module, inspect the label and terminal markings first. Because the documents show different C0/C1/C2 layouts, do not fit bridges using an unrelated drawing.

A relay click does not prove contact condition. Test each output with a suitable load and check for sticking, intermittent contact and abnormal heating.

One output may remain below its rating while the shared COM is overloaded. Add the currents of valves and contactor coils that operate simultaneously.

Verify S/S wiring before connecting sensors. If an input LED changes but the expected X device does not, check the expansion order and address map first.

Do not power all panel sensors from the auxiliary 24 V output without calculating the load. If the documented 100 mA budget is insufficient, use a suitable external supply with the correct common reference arrangement.

Back up the CPU program before maintenance. Use output forcing only during controlled tests; remove every force and recheck protective functions before returning the machine to operation.

PDF documents

Start with our Delta DVP PLC files page. The model archive includes the 2024 Module Manual (English), 2009 ES2 DIDO instruction sheet (English), 2024 DVP catalogue, 2025 ES2/EX2 shared programming manual and 2019 cable selection guide. Turkish page content does not imply that these manufacturer PDFs are available in Turkish.

DVP32XP200R main page | ES2/EX2 modules | DVP expansion modules | DVP PLC series | Used Delta PLC category | Delta Automation

External references

Delta – DVP Series Module Manual, 2024 | Delta – DVP-ES2 DIDO instruction sheet, 2009 (RTS copy) | Delta – PLC/HMI Cable Selection Guide, 2019