Delta TP04P and TP70P combine an operator interface and PLC control in one enclosure. The operator monitors machine status, changes setpoints and issues commands while the built-in PLC executes the control program. Remote I/O is separate field hardware accessed over a communication link. Select the system by considering display requirements, local I/O count, signal types and communication tasks together.
Main differences between TP04P and TP70P
Delta TP04P uses a 4.1-inch, 192×64-pixel monochrome display and physical keys. Delta TP70P provides a 7-inch, 800×480-pixel colour touchscreen. Physical I/O configuration varies by exact model in both families. Matching I/O counts do not establish direct compatibility of screen projects, terminal arrangements or panel cutouts.
Standard models use a nominal 24 V DC supply. Count pushbutton and sensor inputs, relay-controlled loads, analogue transmitters and temperature sensors separately. Voltage, current and Pt100 connections perform different measurement functions.
TP04P relay-output models
Delta TP04P-16TP1R: 8 digital inputs and 8 relay outputs.
Delta TP04P-32TP1R: 16 digital inputs and 16 relay outputs.
Delta TP04P-22XA1R: 8 digital inputs, 8 relay outputs, 4 analogue inputs and 2 analogue outputs; analogue channels support voltage/current signals.
Delta TP04P-21EX1R: 8 digital inputs, 8 relay outputs, 2 current inputs, 1 current output and 2 Pt100 inputs.
TP70P relay-output models
Delta TP70P-16TP1R: 8 digital inputs and 8 relay outputs.
Delta TP70P-32TP1R: 16 digital inputs and 16 relay outputs.
Delta TP70P-22XA1R: 8 digital inputs, 8 relay outputs, 4 analogue inputs and 2 analogue outputs; analogue channels support voltage/current signals.
Delta TP70P-21EX1R: 8 digital inputs, 8 relay outputs, 2 current inputs, 1 current output and 2 Pt100 inputs.
Delta TP70P-RM0 is a PLC-integrated panel without built-in physical I/O. External field signals require suitable communication and I/O hardware. Check its program capacity and port functions against the model's own documentation. R/T suffixes also distinguish output technologies; review field wiring before replacing a relay model with a transistor version.
Local I/O, remote I/O and external terminals
Local I/O means the physical inputs and outputs built into the panel. With remote I/O, field signals connect to a separate I/O station, and the controller exchanges data with that station using a suitable protocol. Assess Delta DVP remote I/O modules and Delta HMI remote I/O modules according to their supported product families and connection requirements.
For example, Delta RTU-485 is a remote I/O communication module providing Modbus access to compatible DVP Slim I/O modules. It operates as a Modbus slave. Integrating such a station into a TP-based system requires confirmation of the host's master function, supported commands, register mapping and PLC program. An RS-485 port alone does not establish compatibility.
Delta external terminals and Delta AH external terminals provide field-wiring termination points for compatible modules. A passive terminal board does not create another PLC controller or a communication-based remote I/O station. Specify the panel, remote I/O adapter, I/O modules and terminal boards by their separate functions.
Programming and communication
Panel pages and operator functions are prepared in Delta TPEditor. PLC logic uses Delta WPLSoft or Delta ISPSoft with confirmed support for the exact model. Preserve the screen project, PLC program and device settings together. Include remote I/O addresses and channel configuration in the project backup.
Distinguish USB programming from field communication. Standard TP04P and physical-I/O TP70P models provide RS-485 communication and Modbus ASCII/RTU options; check RM variants separately. When selecting Delta PLC cables and HMI programming and HMC cables, match electrical standards, pin assignments, station addresses, baud rate, parity and protocol.
Selection and replacement checks
Identify local and remote I/O points first, followed by relay/transistor loads and analogue requirements. Check panel cutout, rear-terminal clearance, supply capacity and existing project files. For remote I/O, define and test communication update time, timeout handling and output behaviour following loss of communication.
Editor's Note
Start with the rear label and terminals. Similar front panels may conceal digital-only, analogue or temperature-input configurations. Confirm the complete code and clear terminal photographs before ordering a replacement.
Before removing a working controller, save the screen project, PLC program and communication settings. If remote I/O is fitted, record station addresses and module order as well. Files stored in the panel may not describe the complete installation.
Do not judge relay health by clicking sounds. Test contacts with a suitable small load in a safe bench setup. Check analogue channels with known signals and Pt100 inputs with a suitable sensor or simulator. A normal-looking display does not prove that all measurement channels work.
For remote I/O, test more than normal operation with the cable connected. In a safe setup separated from the machine, disconnect communication and observe alarms and output behaviour. A retained screen reading does not establish that the data is still current.
For intermittent resets or communication faults, check the loaded 24 V supply, loose terminals, corrosion and signal-cable routing first. During repair, examine connector joints and supply circuitry. Before transferring old wiring to another model, compare output technology, commons and the program.
Site resources and PDF pages
Use Delta TP panel files for series documents and Delta HMI Files or Delta PLC and HMI manuals for wider document selection. Match each document to the exact panel and remote I/O hardware.
Related topics
For separate PLC architectures, see Delta DVP PLC series, Delta AS PLC series and Delta AH PLC series. Delta DVP-ES and Delta DVP14ES00R2 describe relevant DVP models; these links do not establish direct hardware interchangeability with TP panels.
Continue connection and auxiliary-hardware selection under Delta PLC accessories.