Delta TP70P-16TP1R
Delta TP70P-16TP1R 7-Inch HMI with Built-In PLC — 8 Inputs, 8 Relay Outputs
Delta TP70P-16TP1R combines a 7-inch TFT LCD touchscreen, built-in PLC functions, 8 digital inputs and 8 relay outputs within the Delta TP70P family. Display resolution is 800 × 480 pixels and the nominal supply is 24 V DC. Within the TP panels and remote I/O group, it provides an operator interface and local on/off control for machine applications.
16TP1R does not mean 16 inputs: the unit has 8 inputs and 8 outputs, giving 16 digital I/O points in total. This version has no built-in analog inputs, analog outputs or Pt100 inputs. Selection should follow the actual signal list and output technology required by the machine as well as screen size.
Display and cabinet mounting
Overall dimensions are 205.6 × 142.6 × 49 mm, with a nominal panel cutout of 191 × 128 mm. Apply the tolerances and cabinet-sheet requirements in the manufacturer’s mounting drawing. When checking mounting and power connections, allow room for the gasket, fixing parts and wiring to the rear I/O terminals.
Digital inputs and addressing
Inputs are addressed X0–X7 and outputs Y0–Y7. For 24 V DC sensors, check the PNP/NPN output arrangement together with the S/S0 (S/S) input common. The manual specifies maximum input frequencies of 10 kHz for X0 and X1 and 60 Hz for the other digital inputs. Pulse-counting applications also require verification of signal levels, input filtering and the counter configuration in the program.
Relay outputs and load selection
The stated resistive-load rating is 1.5 A per output and 5 A per COM group; the switching-voltage table specifies 250 V AC and below 30 V DC. Treat the per-output rating and the total common-group current as separate limits. For contactors, valves and other inductive loads, check inrush current, contact life and suitable suppression rather than applying the resistive-load figure directly.
Communication ports and programming
COM2 and COM3 are RS-485 interfaces. COM2 operates in PLC mode and is configured through special PLC M/D devices; COM3 operates in Text panel mode and is configured through panel objects. On the DB9 connector, COM2 D+/D− use pins 6/7, COM3 D+/D− use pins 8/9, and signal GND is pin 5. Check connector orientation against the manufacturer’s drawing. Select communication peripherals and programming cables for the actual port duty.
The USB Type-B port provides the computer connection. Use TPEditor for the screen project and WPLSoft for PLC program transfer and monitoring. If ISPSoft is used, verify target-device support and the existing project version. When selecting Delta PLC software, retain separate backups of the screen and PLC projects.
Other models in the family
Consider TP70P-32TP1R for more digital I/O, TP70P-22XA1R for analog signals, and TP70P-21EX1R for applications involving analog and temperature inputs. TP70P-RM0 is a different version without physical I/O. The Delta TP04P group provides smaller-panel options. Any change between models requires a new comparison of the program, terminal arrangement and communication duties.
Editor’s Note
Start with the correct count: 8 inputs plus 8 relay outputs. Do not plan for 16 sensors just because the model contains the number 16. Prepare separate input and output lists before choosing the hardware.
Seeing Y0 ON in the program does not prove that its relay contact switches a load correctly. Have every output on a used unit checked with a suitable test load, distinguishing welded contacts, intermittent switching and common-connection faults.
An input that does not respond is not automatically a failed board. Check the sensor output type, S/S common connection and actual input voltage first. For counting applications, remember that X0/X1 and the other inputs have different speed ratings.
Test more than the centre of the touchscreen. Check all four corners, small buttons and dragging movements. Observe the backlight during cold startup and again after the unit has warmed up.
Before experimenting with a panel removed from a working machine, obtain both screen and PLC backups. Record passwords, communication addresses and machine-specific settings. Preserve the existing project during diagnosis.
Disconnect machine loads for bench testing. Check USB communication, both RS-485 channels and physical I/O separately. Remove power before changing wiring or dismantling the unit; a working startup screen is only one part of the test.
PDFs and technical documents
Use documents matching this model on the Delta TP panel files page. In TP70P Quick Start, refer to section 1.5.1 for I/O, 1.6.3 for relay loads, and 1.9 and 3.2 for communication connections. Explore Delta PLC and HMI manuals for other document groups.
Related topics
Explore the Delta PLC family and Delta PLC accessories for controller, connection and auxiliary-hardware options. Browse used Delta equipment for listed units, or Second Hand Models to search other brands by equipment type. Confirm the complete nameplate, condition and included items with the store responsible for the listing.
External reference
TP70P-16TP1R installation and pin-assignment sheet — multilingual, including English and Turkish. A copy of the manufacturer’s sheet hosted by panele-hmi.pl.
Delta TP70P Quick Start — English, 10 January 2020. A copy of Delta’s manufacturer manual hosted in the Kalatec archive. Use the TP70P-16TP1R column and the applicable wiring drawings.