Delta Servo Power Connectors

Delta Servo Power Connectors

Delta servo power connectors connect the servo drive’s power cable to the servo motor. In a servo system, the model-specific drawing identifies the U/V/W motor phases, protective earth and holding brake contacts where fitted. The encoder and its feedback signals use a separate connector and cable.

Part numbers and connector types

ASDBCAPW0000 · Power connector Delta lists for applicable ASDA-B2 motor combinations without a brake.

ASDBCAPW0100 · Power connector with brake contacts for applicable combinations. For example, Delta lists the 0000 or 0100 code for ASD-B2-0421-B and ECMA-C△0604□S, depending on the brake option.

ASD-CAPW1000 · Circular power connector. The Delta ASDA-A2 catalogue drawing identifies it as MS 3106A-20-18S.

ASD-CAPW2000 · Circular power connector. The Delta ASDA-A2 catalogue drawing identifies it as MS 3106A-24-11S.

Two connector options for the same 2 kW drive

For ASD-B2-2023-B + ECMA-C△1020□S, Delta lists the ASD-CAPW1000 connector and the ASDBCAPW120X / ASDBCAPW130X cable families. For ASD-B2-2023-B + ECMA-E△1820□S, the connector is ASD-CAPW2000 and the cable families are ASD-CAPW220X / ASD-CAPW230X. In each pair, the first cable is for a motor without a brake and the second is for a brake-equipped motor.

Verify the motor and drive combination, then select the connector by the complete motor code. When selecting a motor, check the frame and brake options alongside speed and torque requirements. The ASDA-A3 catalogue also lists standard and IP67 connector options by frame size.

Editor’s Note

1. Show the motor nameplate and existing plug when ordering. Ask for a head-on photo of the motor socket and a photo showing the plug’s cable exit. During the inspection, check the alignment key, locking mechanism, threads and cable clamp. Specify whether the quote is for a connector kit or a complete cable.

2. Check the viewing direction in the drawing. With the system safely isolated and the cable disconnected, use a multimeter to check continuity against the manufacturer’s drawing. Check protective earth, shield termination and power and signal cable routing against the panel schematic.

3. Record heating and feedback dropouts separately. If you find a loose or discoloured contact, record where the heating occurs. If feedback errors coincide with contactor switching, include EMI filtering and EMC conditions in the checks.

4. Check the holding brake and braking resistor separately. For the motor brake, check the connector’s brake contacts and the machine schematic. If a fault occurs during stopping, record the deceleration time. For a regeneration fault, check the braking resistor against the exact drive model.

5. Verify basic functions after replacement. Under the machine’s test procedure, check direction, feedback and brake release where fitted during a controlled low-speed run. Confirm the response to a known position command before reviewing loop gains or auto-tuning.

Connector drawings and technical documents

ASDA-B2 — Power Connector Drawings (PDF) · English, 2023, 351 pages. PDF page 334 shows the four connectors and page 346 shows the 2 kW motor pairings.

ASDA-A2 — Power Connector Catalogue (PDF) · English, 2023, 72 pages. PDF page 52 covers connector drawings and circular plug designations.

ASDA-A3 — Standard and IP67 Power Connectors (PDF) · English, 2025, 102 pages. PDF page 86 lists connector options by frame size.

Related Delta equipment

ASDA-B2 · ASDA-A2 · ASDA-A2R · ASDA-A3 · ASDA-B · ECMA servo motors

Servo cables · Encoder connectors · Servo I/O connections · DC bus units · Servo braking resistors

Delta Servo Modules and Accessories · Used Servo Drives · Delta Servo Manuals

External reference — Delta ASDA-B2 connector drawings