Delta Servo STO Connections
Delta Servo STO Connections and ASD-CNFS0808
STO (Safe Torque Off) is a safety function that prevents the servo drive from producing motor torque. When STO activates, active speed and torque control ends. A moving axis can coast to a stop. If the machine requires controlled deceleration first, assess a suitable safety function such as SS1 as part of the risk assessment.
The motor holding brake, dynamic braking and STO serve different functions. A braking resistor helps manage regenerated energy during deceleration. The drive supply and DC bus can remain live while STO is active. Follow the machine’s isolation and absence-of-voltage verification procedure before service. See drive safety functions for further background.
Delta STO connectors and channel terminals
ASD-CNFS0808 is an accessory pack of eight STO connectors listed in the Delta ASDA-A2-E catalogue. Check the exact drive model, hardware revision and fitted socket before ordering. The catalogue states that STO is unavailable on the 4.5–7.5 kW drives in the 200 V class.
ASDA-A2-E · CN-STO. The 2022 manual identifies channel A at 2–3 (STO_A, /STO_A), channel B at 4–5 (STO_B, /STO_B) and the monitoring terminals at 6–7 (FDBK_A, FDBK_B). The safety relay wiring diagram is in section 7.1.
ASDA-A3 and ASDA-B3A · CN10. In the relevant CN10 tables of the 2025 ASDA-A3 and ASDA-B3 manuals, channel 1 is at 3–4 (SF1+, SF1−), channel 2 is at 5–6 (SF2+, SF2−) and diagnostic output is at 7–8 (EDM+, EDM−). The B3 manual documents STO for B3A hardware. Choose the B3A SIL 3 or SIL 2 section that matches the drive’s certification. For A3, match the exact model and hardware revision to the relevant manual as well.
How the dual-channel safety circuit works
An emergency stop or guard demand goes to a safety relay or safety PLC. Its two outputs control the two STO channels on the drive. Verify the suitability of relay contacts or pulsed solid-state outputs against both device manuals. Use FDBK and EDM for diagnostics and monitoring. A standard limit switch signals the end of axis travel.
Selection of an emergency stop button, guard interlock or safety light curtain starts with the machine risk assessment. Verify the required SIL or PL against the full circuit and its operating conditions. Hardware measures such as SFF and HFT form part of that assessment. On machine tools, assess stopping time and the conditions for unlocking the guard together as part of the CNC safety design.
Editor’s Note
Read the label before handling the plug. Look for CN-STO on A2-E and CN10 on the applicable A3 and B3A drives. Two diagrams can show eight terminals with different channel and diagnostic assignments. Check whether the diagram shows the drive socket or the cable plug.
Record the alarm before resetting it. On A2-E, AL500 indicates active STO and AL501/AL502 indicate a channel signal loss or error. Record the safety relay diagnostics and both channel states at the time of the fault. Trace the signal path in the machine schematic before considering changes to drive settings.
For faults during acceleration, inspect loose terminals, moving cables, supply voltage drop, cable routing and grounding. If you suspect electromagnetic interference, record the motion or load conditions that reproduce the fault.
Secure the load first on a vertical axis. Gravity can move the load once motor torque is removed. After replacing a drive, check load holding and stopping distance during maintenance and validation. Follow the machine test plan to verify that motion requires a separate start command after a safety reset.
Delta STO wiring diagrams and PDFs
ASDA-A2-E catalogue — ASD-CNFS0808 · English. Printed page 5, connector pack and ordering code.
ASDA-A2-E — CN-STO and safety relay wiring · English. Section 7.1, terminal table and wiring diagram on the following page.
ASDA-A3 — CN10 connections · English. Section 3.10.6, 2025 manual.
ASDA-B3A · 2025 manual, English. CN10 SIL 3 wiring · CN10 SIL 2 wiring.
Related Delta equipment
Servo I/O connections · Servo cables · Servo braking resistors · DC bus units
Delta Servo Modules and Accessories · Used Delta equipment · Delta Servo Manuals archive
External sources · A2-E accessory table · A2-E manual · A3 manual · B3 manual · INRS definitions of STO and SS1