Delta ECMA Motors with Magnetic Encoders

Delta ECMA Motors with Magnetic Encoders

On the Delta ECMA servo motors in this group, the M after C or G in the motor code identifies a 13-bit magnetic encoder. Before ordering, check the complete motor code, the servo drive and the feedback cable together.

Model codes and motor characteristics

All four models are in the 220 V class. The CM models are rated at 3,000 rpm, and the GM models at 1,000 rpm. In these codes, P denotes a keyed shaft with a fixing screw hole, supplied without a brake or oil seal. S denotes the standard shaft diameter.

When selecting a motor, compare frame size, shaft, rated speed and load inertia together. Both closed-loop feedback and the mechanical transmission affect positioning accuracy.

ASDA-B2 drive and encoder cable pairings

ECMA-CM0604PS · 400 W, 60 mm frame, low inertia · ASD-B2-0421-B · Encoder cable ASDBCAEN000X.

ECMA-CM0807PS · 750 W, 80 mm frame, low inertia · ASD-B2-0721-B · Encoder cable ASDBCAEN000X.

ECMA-GM1306PS · 600 W, 130 mm frame, high inertia · ASD-B2-0721-B · Encoder cable ASDBCAEN100X.

ECMA-GM1309PS · 900 W, 130 mm frame, high inertia · ASD-B2-1021-B · Encoder cable ASDBCAEN100X.

These motor and drive pairings come from Appendix A of the ASDA-B2 manual. Delta lists the 600 W motor with a 750 W class drive and the 900 W motor with a 1 kW class drive. Check the application’s speed and torque requirements against the motor’s own ratings.

CN2 and the motor-side connector

The encoder cable connects to CN2 on the drive. Look up the complete motor code in section 3.1.5 for the motor-side connector and terminal layout. Check encoder signals, grounding, and cable shielding and routing together.

Editor’s Note

1. Ask for photos of the nameplate and connector. The M code and PS suffix should be legible. During a used motor inspection, check shaft play, keyway wear and the connector latch.

2. Check the cable family before ordering. The CM0807PS and GM1306PS are both listed with the ASD-B2-0721-B. For a 3 m cable, Delta lists ASDBCAEN0003 for the CM0807PS and ASDBCAEN1003 for the GM1306PS. Verify the part number and both ends of the existing cable.

3. Record AL011 and AL024 separately. AL011 indicates an encoder error. AL024 indicates an encoder initial magnetic field error. Save the alarm history from P4-00–P4-04. With the system safely isolated, inspect CN2 and the motor-side connection. For AL024, the manual also calls for checking shielding, grounding and separation from power wiring.

4. Record command scaling before replacing the drive. When backing up the drive configuration, capture the pulse format, electronic gear ratio and command direction. After replacement, check actual axis travel against a known position command.

5. Compare motor inertia before replacement. Review loop gains and auto-tuning conditions for the new motor and load. During a controlled low-speed test, verify the direction of travel and the operation of the travel limit switches.

6. Record the conditions of a stopping fault. Note the speed, load and deceleration time when the alarm occurs. If it involves regenerative energy, compare the braking resistor with the table for the exact drive model.

Technical document

Delta ECMA Magnetic Encoder Motors — ASDA-B2 Matching Table (PDF) · English, 21 April 2023, 351 pages. The link opens PDF page 55, which lists all four motors. See page 17 for the model code, 51–54 for encoder connectors and 341, 343 and 345 for cable part numbers.

Related Delta equipment

Delta ASDA-B2 drives · ASDA-B2-F · ASDA-B2L · ASDA-B3 · Delta ECMA · Legacy ECMA 2,500 PPR · ECM-A3H · ECM-A3L

Servo cables · Encoder connectors · Servo power connectors · Delta Servo Motors · Used Servo Drives · Delta Servo Manuals

External reference — motor table in the Delta ASDA-B2 manual