Delta ASDA-B2L
Delta ASDA-B2L Servo Drive
Delta ASDA-B2L is a 220 V class AC servo drive family. Delta provides a dedicated matching table for the medium-inertia ECM-E2M servo motors used with B2L drives. When replacing a drive in packaging, feeding or positioning applications, check the existing motor, cable set and command format together.
Model codes, supply and motor matching
The 200 W ASD-B2L-0221-B, 400 W ASD-B2L-0421-B, 750 W ASD-B2L-0721-B and 1 kW ASD-B2L-1021-B have supply code 21, which Delta defines as 220 V single-phase or three-phase. The 2 kW ASD-B2L-2023-B and 3 kW ASD-B2L-3023-B have code 23 for 220 V three-phase. These are drive power classes. Use the complete drive code to look up the matching motor in the manual.
For the ASD-B2L-0421-B, Delta lists two 400 W motor patterns, ECM-E2M-C△0604□S0 and ECM-E2M-C△0804□70. When selecting a motor, compare the frame, brake and shaft options alongside the power rating. The △ in the motor code identifies the encoder type. Check feedback compatibility across the motor, drive and cable set as part of checking the servo axis components.
CN1 command input and position settings
In external pulse-train position control, commands enter through CN1. P1-00 selects A/B phase, CW/CCW, or pulse and direction. P1-44 and P1-45 set the first numerator and the denominator of the electronic gear ratio. After a drive replacement, verify the commanded travel and direction to preserve positioning accuracy.
For axes using speed or torque control, record the command source as well. Identify the analog and digital signals separately. For digital inputs, compare the NPN/PNP output type, input common and travel limit switch states with the machine schematic.
Editor’s Note
1. Get all three identifiers. For a used set, ask for the drive and motor nameplates and the cable part number if available. During the maintenance inspection, check shaft play, signs of oil ingress and the CN2 connector latch.
2. Match the 750 W drive’s cable to the motor. Appendix A lists both a 750 W and a 1 kW motor for the ASD-B2L-0721-B. The two pairings use different power cable families. Order by complete motor code and brake option.
3. Keep the original settings. When backing up the drive configuration, record P1-00, P1-44/P1-45 and input assignments separately. Verify command direction and scaling before changing loop gains or evaluating auto-tuning.
4. Check the CN2 path for AL011. Record the alarm history from P4-00–P4-04. With the system safely isolated, inspect both ends of the encoder cable and its connectors. If the fault recurs during motion, check grounding, shield termination and signal cable routing.
5. Record when the alarm occurs. If it appears during a hard stop, review acceleration and deceleration times, load inertia and the alarm history together. For a regeneration alarm, check the braking resistor against the table for the exact drive model.
6. Ask for a test record. For a used set, the video should show both nameplates, a controlled low-speed run in both directions, stopping and the alarm display. For a brake motor, ask for a separate demonstration of brake release and holding.
User manual and PDF archive
Delta ASDA-B2/B2L User Manual (PDF) · Chinese, 21 April 2023. Chapter 1 covers model codes and B2L motor matches, Appendix A lists the power and encoder cables, and Chapter 9 covers alarms.
Related Delta equipment
Delta servo motors · Delta ECMA motor family · Servo cables · Encoder connectors · Servo braking resistors · Servo accessories
Delta ASDA-B2 · Delta ASDA-B2-F · Delta ASDA-B3 · Delta ASDA-A3 · Delta AS PLC · Delta AH motion controllers
Delta Servo Manuals · Delta Servo Drives · Used Servo Drives