Delta DVP64ES300T

Delta DVP64ES300T DVP-ES3 PLC

The Delta DVP64ES300T is a compact PLC CPU from the Delta DVP-ES3 series with 32 digital inputs and 32 NPN transistor outputs. It runs on 100–240 V AC and has a program capacity of 64k steps. Its onboard I/O suits industrial automation applications such as conveyors, sorting and packaging with many field signals.

Digital I/O and high-speed signals

The X0–X37 inputs accept 24 V DC signals. When wiring an inductive sensor or photoelectric sensor, check the S/S0 and S/S1 commons against the PNP/NPN signal type. The Y0–Y37 NPN outputs sink load current to 0 V. They switch 5–30 V DC resistive loads up to 0.5 A per point. When designing the control panel, allow for the 4 A limit per common group and the external 24 V DC supply at UP/ZP. If an interposing relay is required, check its coil current and suppression.

X0–X7 form the 200 kHz input group. When connecting an encoder, select the input pair to match the encoder output type and high-speed counter mode. Y0–Y7 form the 200 kHz high-speed pulse group and support up to four axes using pulse and direction signals. For positioning, match the pulse input on the servo drive or stepper drive to the PLC’s NPN outputs.

Programming software, cable and communications

Delta lists ISPSoft and DIADesigner for this CPU. For CPU firmware V1.04.00 and later, the manual specifies ISPSoft V3.13 or later or DIADesigner V1.30 or later. Select the DVP-ES3 CPU profile in the PLC programming project. Connect the computer to the Mini USB port with a USB-A to Mini-B data cable. For a network connection, use an RJ45 Ethernet cable and the PLC’s IP address. Configure the ISPSoft connection in COMMGR.

The CPU provides two RS-485 communication ports, RJ45 Ethernet and a CAN interface. For operator panel or SCADA integration, use Modbus over RS-485 with Modbus RTU on a serial link, or Modbus TCP over Ethernet. For CANopen, check drive compatibility and node IDs against the project settings. Record the port assignments and IP address in the panel’s industrial communications documentation.

Editor’s Note

On a used unit, start with the DVP64ES300T label. Check that the removable terminals are all present and inspect the latches and screw slots.

If the original CPU is accessible, back up the program and PLC parameters. Record the COM1, COM2 and IP settings separately.

On the bench, verify both input groups using a known 24 V DC signal and check the output groups with a suitable DC test load.

If the machine uses a servo or stepper axis, measure the pulse and direction signals on Y0–Y7 separately. Use an oscilloscope to check the high-speed pulses.

When changing the CPU, check the AC supply, DC load circuit and panel grounding against their wiring diagrams. Archive the microSD contents if a card is fitted.

Related models and documents

For the same 32 inputs and 32 outputs with relay outputs, see the DVP64ES300R. For 24 inputs and 24 outputs, compare the DVP48ES300T and DVP48ES300R. For 40 inputs and 40 outputs, see the DVP80ES300T and DVP80ES300R.

For smaller panels with 16 inputs and 16 outputs, see the DVP32ES300T and DVP32ES300R. The DVP32ES311T has a 24 V DC supply. Check its power and terminal arrangement when comparing models.