Delta DVP32ES300R

Delta DVP32ES300R | DVP-ES3 PLC with 16 Digital Inputs and 16 Relay Outputs

The Delta DVP32ES300R is a DVP-ES3 PLC CPU with a 100–240 V AC supply. It has 16 digital inputs rated at 24 V DC, 16 relay outputs, and a 64K-step program capacity. It handles sensor and push-button signals for sequential control in conveyor, packaging, and pump panels.

Inputs, relay outputs, and terminals

Inputs: X0–X7 and X10–X17. When wiring an inductive sensor or photoelectric sensor, connect the S/S common to suit the sensor's PNP or NPN output. The sinking and sourcing guide explains the common-terminal arrangement.

Outputs: C0 is the common for Y0–Y7, and C1 is the common for Y10–Y17. Delta rates resistive loads at 2 A per output and 5 A per common. When switching contactor coils with the relay contacts, account for the load type, inrush current, and coil suppression. Consider the transistor-output model for applications requiring high-speed pulse outputs.

Which software and cable do you need?

Program the DVP32ES300R with ISPSoft or DIADesigner. For direct connection, use a data cable with a USB Mini-B plug at the PLC. For network access, use an RJ45 Ethernet cable. Select the connection type in COMMGR. See the guides to PLC programming, ladder diagrams, and PLC cables for setup.

Communication: The CPU has two RS-485 ports, one 10/100 Mbit/s Ethernet port, and a CANopen interface. Use Modbus RTU for serial devices and Modbus TCP or EtherNet/IP Adapter for compatible Ethernet devices. Check the protocol and device addresses when adding an HMI panel or remote I/O.

Editor's Note

Check the label. When buying a used unit, confirm the full model number and check that all removable terminal blocks are present.

Identify the supply and signal terminals. Mains power goes to L and N. The 24 V DC field signals go to the X inputs.

Test both relay banks. Use a low-power test load to check the outputs one at a time through C0 and C1.

Make a backup. Before replacing a CPU, save the project, IP address, and serial communication settings.

Check the cable routing. Keep signal wires away from drive output cables. The guides to electromagnetic interference and panel grounding cover common causes of intermittent faults.

Related models

DVP32ES300T AC supply, 16 inputs / 16 transistor outputs • DVP32ES311T 24 V DC supply, 16 inputs / 16 transistor outputs • DVP48ES300R 24 inputs / 24 relay outputs • DVP64ES300R 32 inputs / 32 relay outputs

Related guides and PDF files

Ethernet cable types • Ethernet switches and hubs

Delta DVP32ES300R model page • Used Delta PLC models • Delta DVP PLC PDF files

External references · Delta DVP-ES3 installation and wiring sheet · Delta DVP-ES3/EX3/SV3/SX3 hardware manual