Delta DVP64ES300R

Delta DVP64ES300R – ES3 PLC with 32 inputs and 32 relay outputs

Delta DVP64ES300R is a 100–240 V AC CPU in the DVP-ES3 series. It has 32 digital inputs at 24 V DC and 32 relay outputs, a 64K-step program capacity, removable terminal blocks and support for up to 256 I/O points with expansion. A conveyor or packaging panel can use it to read photoelectric sensors and limit switches and to control valves and contactors.

Digital inputs and relay commons

X0–X37 use octal addressing. S/S0 serves X0–X17 and S/S1 serves X20–X37. Wire each group for the PNP or NPN sensors in use. The input table gives maximum frequencies of 200 kHz for X0–X7, 10 kHz for X10–X17 and 50 Hz for X20–X37. For an encoder, also check the input assignments and the A/B mode limit of the high-speed counter.

The Y0–Y37 relay outputs are arranged in four groups of eight. The supply commons are C0 (Y0–Y7), C1 (Y10–Y17), C2 (Y20–Y27) and C3 (Y30–Y37). Delta specifies 10–250 V AC or 5–30 V DC and a resistive-load limit of 2 A per output, 5 A per common. The mechanical relay contacts respond in about 10 ms and switch at up to 1 Hz. For pulse control, see the transistor-output DVP64ES300T.

Programming software and cable

Program the DVP64ES300R in ISPSoft or DIADesigner in DIAStudio. Select the DVP-ES3 CPU target. Connect the computer to the PLC with a USB Mini-B data cable. On the first connection, install the Delta USB driver and check the COM port assigned by Windows. In ISPSoft, select that port in the COMMGR channel. You can also connect over Ethernet if the existing IP settings are known.

Communications and expansion

COM1 and COM2 are RS-485 ports. For example, one port can serve an operator panel and the other a drive network. Match station addresses, baud rate and parity for Modbus RTU. The single 10/100 Mbps Ethernet port supports Modbus TCP and EtherNet/IP. The built-in CAN port supports CANopen DS301.

All 64 onboard points are digital. To measure pressure or temperature or send a speed reference to a drive, choose compatible analog I/O from the DVP expansion modules. Check the module order and CPU power budget in the hardware manual before installation. The CPU also has a microSD slot for cards up to 32 GB.

Editor’s Note

Ask for the full model label when buying used. Confirm the R suffix and identify C0–C3 in the photos. Check that all removable terminal blocks are included and look for heat marks around them.

Use a small load to test the output. The Y LED shows the PLC command. Use a suitable 24 V DC test load and a multimeter to check whether the relay switches the load. Sample outputs from all four common groups.

Check the total current in each group. Add up the loads on each C terminal. Use an appropriate diode for a DC coil, the manufacturer’s specified suppressor for an AC coil, and suitable fusing for each group.

Start with USB. If the network address of a used CPU is unknown, go online through Mini-B first. Read and record the IP settings and the parameters for both serial ports.

Back up before replacing the CPU. With the machine in a safe state, save the project, hardware settings and retained data. Check the X inputs, Y outputs and connected devices in sequence before returning the machine to service.

Related topics and similar PLCs

DVP32ES300R 16 inputs/16 relays · DVP48ES300R 24 inputs/24 relays · DVP80ES300R 40 inputs/40 relays · DVP64ES300T 32 inputs/32 NPN outputs

Delta DVP PLC series · Used Delta PLCs · Delta main page · How PLC inputs and outputs work

PDFs and manuals

Delta DVP PLC PDF files

External references · DVP-ES3 instruction sheet (TR/EN) · DVP-ES3 hardware and operation manual (EN) · DVP-ES3 programming manual (EN)