Delta DVP80ES300R
Delta DVP80ES300R – DVP-ES3 PLC with 40 Inputs and 40 Relay Outputs
The Delta DVP80ES300R is a compact PLC CPU in the Delta DVP-ES3 series. It runs on 100–240 V AC and has 40 built-in 24 V DC digital inputs and 40 relay outputs. Program capacity is 64K steps. The system supports up to 256 I/O points with expansion. Removable terminal blocks simplify maintenance and CPU replacement on machines with extensive field wiring.
Digital inputs, relay outputs and expansion
The built-in inputs are addressed X0–X47 and the outputs Y0–Y47 in octal. The input commons are S/S0 and S/S1. The relay group commons are C0–C4. When wiring limit switches or inductive sensors, use the appropriate PNP or NPN diagram for the input group. Delta specifies a hardware input frequency of up to 200 kHz for X0–X7. For an encoder, also check the channel and frequency limits of the selected high-speed counter mode.
Use the relay outputs to switch suitable panel loads such as pilot lights and interposing relays. Delta’s 2023 hardware table specifies 2 A per output and 5 A per common for resistive loads. For contactor or valve coils, also consider inrush current, contact life and suitable coil suppression. For pulse-and-direction positioning, see the DVP80ES300T, which has the same I/O count and NPN transistor outputs.
Add compatible Delta DVP expansion modules if more field I/O is required. Delta lists the DVP08XM211N as a digital input module and the DVP08XN211R as a relay output module. Check the module order, power budget and I/O addresses in the project together.
Programming software, USB cable and communications
Use Delta ISPSoft or DIADesigner for the standard DVP-ES3 CPU. Delta specifies ISPSoft 3.08 or later for ES3. For a direct PC connection, use a USB-A to Mini‑USB Type B data cable. Create the appropriate USB connection in COMMGR and select it in ISPSoft. For a network connection, use an RJ45 Ethernet cable and check the CPU’s IP settings.
The CPU has one 10/100 Mbps Ethernet port, two RS‑485 ports, a CAN port and a microSD slot. Connect an HMI using Modbus TCP or a serial field device using Modbus over RS-485. The CAN port supports CANopen DS301. When setting up RS-485, match the station address, baud rate and parity to the other device.
Editor’s Note
Read the complete label on a used unit. The DVP80ES300R has relays and the DVP80ES300T has NPN transistors. The terminal blocks look similar, but their common terminal layouts differ.
Photograph and label S/S0, S/S1 and C0–C4 before removing the terminal blocks. This is especially helpful when a panel uses multiple load supplies.
A lit output LED does not confirm that the contact works. Isolate the unit from the machine and check the open and closed states across each relay group on a safe test bench.
If the old CPU still runs, back up the program, hardware configuration, network settings and any retained data the application uses before replacement.
If the USB connection does not appear, check that the Mini‑B cable carries data and that the PC detects the CPU. Then verify the COMMGR connection and project model.