Delta DVP-ES3
Delta DVP-ES3 Series PLC
Delta DVP-ES3 is a third-generation, block-type PLC CPU family with 64k steps of program capacity. It supports digital machine control, high-speed counting, pulse motion and industrial communication. PLC programming for standard ES3 models uses ISPSoft or DIADesigner. Ladder diagrams, tasks and function blocks are organised for the application. ES3 is not programmed with WPLSoft.
CPU options provide 32, 48, 64 or 80 built-in I/O points. A suitable expansion arrangement supports up to 256 total I/O points. Built-in CPU terminals and the system expansion limit are different figures. Select supply voltage, relay/transistor output and standard/EtherCAT variant by the complete ordering code.
ES3 models: I/O and supply differences
32 I/O: DVP32ES300R and DVP32ES300T provide 16 inputs + 16 outputs and require 100–240 V AC CPU power. R identifies relay outputs; T identifies NPN transistor outputs.
48 I/O: DVP48ES300R and DVP48ES300T have 24 inputs + 24 outputs and a 100–240 V AC supply.
64 I/O: DVP64ES300R and DVP64ES300T provide 32 inputs + 32 outputs. 80 I/O: DVP80ES300R and DVP80ES300T provide 40 inputs + 40 outputs. These CPUs also require 100–240 V AC.
24 V DC CPU: DVP32ES311T is a main PLC CPU with 16 inputs + 16 NPN transistor outputs, not an auxiliary expansion module. Although it shares the I/O count of DVP32ES300T, its power connection is different. Do not apply AC mains to the 311T model.
Output types, sensor wiring and addressing
The R suffix identifies relay outputs; T identifies NPN/sinking transistor outputs. Use the appropriate transistor model for high-speed pulse applications. Connect input common S/S for the PNP/NPN sensor circuit. An AC-powered CPU does not accept AC signals at its digital input terminals: ES3 digital inputs use 24 V DC signals.
When using an inductive sensor or photocell, check output polarity, common wiring and response time together. X and Y addresses use octal numbering; X10 follows X7. Correct panel grounding and suitable separation between signal and power wiring are particularly important for stable high-speed inputs.
Which programming software is required?
Standard DVP-ES3 CPUs use ISPSoft or DIADesigner. Select the complete CPU model in the project and match the software release, CPU firmware and required instructions. An ES2, SS2 or SA2 project requires a review of addresses, special registers and hardware configuration before migration; changing the CPU name alone is insufficient.
DVP32ES300TEC requires DIADesigner only. Do not assign standard ES3 ISPSoft support to this EtherCAT variant. WPLSoft is not the programming tool for either standard ES3 or TEC.
COMMGR manages communication between the PC and CPU. Configure the connection driver and target device before going online. Back up the existing project, hardware settings and required retained data before downloading a program.
Which programming cable is used?
USB: Use a standard data-capable USB cable from the PC to the CPU’s Mini-B USB socket. For a PC with USB-A, this is a USB-A → Mini-B cable. Install the manufacturer’s USB driver for first use and configure the USB connection in COMMGR. A charge-only cable cannot transfer program data.
Ethernet: Connect a suitable Ethernet cable to the RJ45 port, configure the PC/PLC IP addresses and subnet, and select the target CPU address in the software. The native ES3 USB connection does not require the USB-to-RS-232 / mini-DIN programming cable used by older DVP models. Select by the actual port standard rather than connector appearance.
High-speed counters, pulse outputs and motion
X0–X7 support input frequencies up to 200 kHz; other input groups have different limits. For an encoder, match A/B phase requirements, electrical output type and counter mode. Do not apply the same frequency rating to every input terminal.
Transistor models provide up to 200 kHz on Y0–Y7, enabling a suitable 4-axis / 8-point pulse arrangement. For a servo or stepper motor drive, match pulse/direction or the selected command format, drive input circuitry and PLC output wiring. These ratings do not apply to relay outputs, and a terminal frequency rating does not establish support for every motion function.
RS-485, Ethernet, CANopen and EtherCAT
Standard ES3 provides two RS-485 ports. In a Modbus RTU network, match station addresses, baud rate, data format and master/slave roles. Correct D+/D− and shield wiring matters as much as matching the software settings.
The built-in network interface supports Modbus TCP and EtherNet/IP. Review the differences between EtherNet/IP and Modbus TCP; devices sharing an RJ45 connection do not necessarily use the same protocol. Verify the required communication role, data mapping and CPU firmware support.
The standard ES3 CANopen interface and the EtherCAT interface on DVP32ES300TEC are different hardware options. TEC does not retain the standard model’s CAN port. Select EtherCAT drives and motion functions using the manufacturer’s model/drive compatibility list rather than assuming compatibility from the connector.
Analog measurement, PID and expansion
A standard ES3 CPU’s digital I/O count does not imply built-in analog signal channels. For voltage/current measurement or PID control, select a suitable analog module, measurement range and scaling. Pt100 and thermocouple sensors require appropriate temperature modules; ordinary digital inputs cannot directly measure them.
When choosing DVP E2 modules, check ES3 support, module order, power budget and hardware configuration. During commissioning, confirm that each installed module is correctly addressed and its field signals correspond to the expected program devices.
Editor’s Note
Start by checking whether the CPU label says 300 or 311. Confusing AC and DC supply variants can damage a healthy controller at first connection. Verify output type at the same time.
A failed WPLSoft connection does not establish a CPU fault. Use ISPSoft/DIADesigner for standard ES3 and DIADesigner for TEC, with the correct target CPU and communication driver.
For USB problems, check the data cable, Mini-B socket and driver first. For Ethernet, check IP address, subnet, cable and link indicators. Separate communication faults from CPU faults before replacing parts.
An output LED is not a completed load test. Test relay contacts with a suitable load and transistor outputs with correct polarity and load supply. For pulse applications, use an oscilloscope where possible to inspect frequency and waveform.
Do not implement the emergency stop solely in a standard PLC program. Review the machine’s safety circuit with suitable hardware and prevent unexpected movement during testing.
Back up the program, hardware configuration and required data. With power disconnected, inspect connectors, the supply and affected I/O circuits as appropriate. Finish with loaded I/O, communication and controlled power-cycle checks.
Manuals and related topics
Use Delta DVP PLC files for hardware, wiring and programming documents. Match the ES3 manual to the complete CPU code, firmware and programming tool. For supporting concepts, see how a PLC works, ladder diagrams and industrial Ethernet protocols.
Navigation: Delta Automation · Delta PLC · Delta DVP PLC series · DVP-ES3 main page · DVP files
External references
Delta ES3/EX3/SV3/SX3 Hardware and Operation Manual, English · Delta ES3/EX3/SV3/SX3 Programming Manual, English · Delta DIADesigner software and device support