Delta DVP32ES300T

Delta DVP32ES300T 32-Point NPN Transistor Output PLC

The Delta DVP32ES300T is a 100–240 V AC Delta DVP-ES3 main unit. This PLC CPU has 16 digital inputs and 16 NPN transistor outputs on removable terminal blocks. It provides 64K steps of program capacity and supports up to 256 total I/O points with compatible DVP expansion modules. Typical applications include labeling, conveyor sequencing and pulse-controlled positioning.

Digital inputs and NPN outputs

The X0–X17 digital inputs accept 24 V DC signals. Wire the S/S common to suit the sensor’s PNP or NPN output. The Y0–Y17 outputs are NPN sinking outputs. The load circuit operates at 5–30 V DC. Delta specifies 0.5 A per output and 4 A per common for resistive loads. Check the 24 V DC auxiliary supply at UP and ZP and the common terminals against the model wiring diagram.

The maximum input frequency is 200 kHz at X0–X7 and 10 kHz at X10–X17. The output switching limit is 200 kHz at Y0–Y7 and 1 kHz at Y10–Y17. Check the pulse and direction input levels when selecting a servo drive or stepper drive. For a line-driver encoder, check the electrical compatibility of the differential signal and the PLC input in the wiring diagram.

Programming software and cable

Use Delta ISPSoft 3.08 or later or DIADesigner for PLC programming. For USB, use a data cable with a Mini-USB B connector at the PLC end. A USB-A to Mini-B cable suits a computer with a Type-A port. Install the Delta USB driver, create a USB (Virtual COM) connection in COMMGR and select the port shown in Windows.

For network programming, use an RJ45 Ethernet cable. Configure the PC for the PLC’s subnet and select the CPU’s IP address in the software. If the machine has an HMI, check the current PLC address and the panel’s communication settings in the project backup before connecting. See the Delta HMI files for panel information.

Communication and storage

The CPU has one 10/100 Mbps Ethernet port and two RS-485 ports. It supports Modbus TCP and EtherNet/IP over Ethernet and Modbus over RS-485 over its serial ports. It also supports CANopen and microSD cards up to 32 GB. When designing industrial communications, check the device roles and data mapping for EtherNet/IP and Modbus TCP.

Editor’s Note

Start with the nameplate. The ES300T CPU takes AC mains power. Check the sensors’ 24 V DC supply and the input common separately.

If an output LED is on and the load stays off, check the load supply and the UP/ZP terminals against the drawing. Use the correct common as the voltage reference.

If an axis misses pulses, check the Y address in the PLC project and the drive’s pulse input settings. The frequency limit depends on the output group.

Before swapping the PLC, back up its program, IP address and serial port settings. Save the HMI and drive parameters as well if the machine uses them.

On the bench, check the RUN and ERROR LEDs first, then test the inputs and outputs separately. See the PLC troubleshooting guide for diagnostic checks.

Related models and topics

The 24 V DC DVP32ES311T and relay-output DVP32ES300R have the same digital I/O count. For more I/O points, see the DVP48ES300T, DVP64ES300T and DVP80ES300T.

See the DIN rail and grounding guides for panel installation and noise control.

Delta DVP PDF files

Delta DVP PLC files · DVP-ES3 / EX3 / SV3 / SX3 Hardware and Operation Manual (English PDF)

Categories · Second-hand models · Delta Automation · Delta PLC · Delta DVP PLC series

External references · DVP-ES3 Instruction Sheet (multilingual PDF) · Delta DVP/TP selection catalogue (English PDF)