Delta UC-DN01Z-01A
Delta UC-DN01Z-01A
Delta UC-DN01Z-01A is a thick, shielded industrial network cable with a PVC jacket for DeviceNet and applicable CANopen installations. Delta specifies 2 × AWG15 + 2 × AWG18, SHLD PVC (Thick). It belongs to the Delta industrial network cables and Delta PLC accessories groups.
The catalogue lists a 305 m roll and ordering by the metre. Roll length is separate from permitted network distance. Prepare the cable for the actual route and state the required delivered length and whether connection hardware is included when ordering.
Thick 01A versus thin 02A
Delta UC-DN01Z-02A is the thin version, with 2 × AWG22 + 2 × AWG24. The larger conductors in UC-DN01Z-01A affect communication distance and power calculations, particularly on long DeviceNet networks. Select between them using the relevant cable and network limits.
Conductors and DeviceNet connections
The thick DeviceNet arrangement uses an AWG15 power pair and an AWG18 data pair. Colours identify red: V+ / 24 VDC, black: V− / 0 V, white: CAN_H, blue: CAN_L, plus the shield/drain connection.
Delta's five-pole DeviceNet terminal diagram shows 1: V−, 2: CAN_L, 3: SHIELD, 4: CAN_H, 5: V+. Do not transfer this numbering directly to an M12 or RJ45 connector; follow the actual port diagram. See Delta network connectors for related connection hardware.
DeviceNet rate and distance limits
The specified maximum DeviceNet communication distances for UC-DN01Z-01A are 500 m at 125 kbit/s, 250 m at 250 kbit/s and 100 m at 500 kbit/s. Thin 02A is specified at 100 m for all three rates. Mixed thick/thin installations require a separate calculation.
The maximum individual DeviceNet drop from the trunk to a device is 6 m. Cumulative drop budgets are 156 m at 125 kbit/s, 78 m at 250 kbit/s and 39 m at 500 kbit/s. Check individual drops, cumulative drops and end-to-end network distance together.
Termination, distribution and power
Terminate both physical ends of the DeviceNet trunk with 121 Ω resistors rated at least 1/4 W between CAN_H and CAN_L. Account for any termination already enabled in distribution hardware. Choose equipment such as Delta TAP-CN01 and Delta TAP-CN02 to suit the trunk/drop arrangement.
Calculate total node current, supply position, cable length and voltage drop together. Thick cable alone does not establish adequate voltage at a remote device. Follow the network grounding plan for shield and drain connections; the shield must not replace V−.
Delta devices and CANopen applications
Delta's DeviceNet examples include DVPDNET-SL, AH10DNET-5A, DVPDT01-S, DVPDT02-H2, RTU-DNET and AHRTU-DNET-5A. Match each device's terminals, network power and operating settings to its own manual.
Delta also shows UC-DN01Z-01A in CANopen examples with DVPCOPM-SL and AH10COPM-5A. Do not automatically carry DeviceNet V+ and pin assignments over to CANopen. Verify the port arrangement when choosing TAP-CN03 for RJ45 drops or TAP-TR01 for applicable CANopen termination. See Delta CANopen cables for ready-made connections.
Editor's Note
A 305 m roll does not establish that a network will operate over that length. Sketch the trunk and every drop before selecting the communication rate. When replacing thin cable with thick cable, include any remaining thin sections in the calculation.
For intermittent communication, measure power at the most distant node while the equipment is operating, as well as at the supply. A loose V+ or V− connection can make a healthy communication module appear faulty.
Check resistance with network power removed. An ideal circuit containing only two parallel 121 Ω terminating resistors measures approximately 60.5 Ω. This helps investigate termination but does not establish the condition of every cable section or device.
If problems begin after adding a device, check drop length, terminal order, a common communication rate and a unique node address in sequence. Avoid changing several settings together; record the result after each step.
For used or cut cable, inspect jacket markings, crushed sections and joints. Correct connections with excessive exposed shielding and avoid unnecessarily untwisting the data pair. Cable carrier, oil resistance and outdoor ratings require separate documentation.
PDF manuals, network configuration and software
Use Delta PLC accessories files for cable selection and wiring resources, and Delta PLC and HMI manuals for device documentation. Select Delta DeviceNet Builder or Delta CANopen Builder according to the tools supported by the connected equipment. The cable itself does not require software loading.
Related topics
UC-DN01Z-02A thin cable · UC-PF01Z-01A PROFIBUS cable · Delta network connectors · Delta CANopen cables
Return to Delta industrial network cables. Browse controllers in the Delta PLC category and available equipment under second-hand Delta products.
External references: Consult the Delta Download Center for manufacturer documentation and the ODVA DeviceNet technology overview for network design information.