Delta DC Bus Units

Delta DC Bus Units

The Delta ASD-MDCP2016 is a DC bus capacitor unit marketed as the C-Box. In a compatible servo drive system, it stores some of the regenerative energy produced during deceleration. The stored energy can be used during the next acceleration.

ASD-MDCP2016 specifications

Delta lists an operating voltage of 250–370 V DC, capacitance of 40,000 µF, input/output current of 60 A RMS and power consumption of 10 W. The manufacturer separately lists a permissible voltage of 450 V DC. The storage limit depends on load inertia.

The C-Box stores energy for subsequent acceleration. A braking resistor dissipates energy as heat during resistive dynamic braking. Use the drive’s braking table and the machine’s duty cycle to select the arrangement. See the technical articles on energy recovery and DC bus chokes for more on these circuits.

Delta ASDA-S drive combinations

ASD-S-5523-N and ASD-S-7523-N · Delta’s CNC catalogue lists an external braking resistor or the ASD-MDCP2016 C-Box as options.

ASD-S-4523-N · The same table lists built-in braking. Verify the complete spindle drive code, motor and installed braking equipment as part of checking the system components.

Editor’s Note

1. Get the C-Box and spindle drive nameplates together. For used equipment, ask for both complete codes and the panel schematic. When selecting the unit, consider load inertia, spindle speed and torque, and how often the spindle stops.

2. Investigate bus overvoltage against the duty cycle. Record spindle speed, the stop that triggers the fault, the cycle time and which axes decelerate together. Review the installed braking equipment and panel thermal management.

3. Have the bus voltage verified before servicing. STO removes motor torque. DC bus capacitors can retain voltage after supply isolation. Before working on connections, qualified personnel should verify isolation and voltage under the manufacturer’s procedure using a suitably rated test instrument.

4. Check field modifications against the schematic. For a retrofit, check the manufacturer’s wiring diagram, protective earth and power and signal cable routing. If communications are also affected, check EMI filtering and EMC conditions separately.

5. Check the model heading on the PDF page. The ASD-MDCP2016 specifications are in the upper table on catalogue PDF page 34. The 24 V DC entry farther down the page belongs to the NC300 CNC controller table. Check the model row before comparing ratings.

Technical documents and application example

Delta ASD-MDCP2016 C-Box — Specifications (PDF) · English, 2019, 44 pages. PDF page 34 covers C-Box specifications, and page 33 lists ASDA-S braking options.

Delta CNC Solution — C-Box Application Example (PDF) · English, 2017, 3 pages. See PDF page 3 for the rigid tapping application.

Related Delta equipment

Delta ASDA-S spindle drives · ECMS spindle motors · ASDA-M · ASDA-A2 · ASDA-A2R · Motion control cards

Servo braking resistors · Power connectors · Servo cables · Servo STO connections

Delta Servo Modules and Accessories · Used Spindles · Delta Servo Manuals

External reference — C-Box specifications in the Delta CNC catalogue