Delta absolute encoder peripheral units include battery boxes and leads that help a battery-backed absolute encoder retain position data when drive power is removed. The box supplies backup power to the encoder on the servo motor. When the servo drive powers up again, it reads the motor position through the feedback connection. That position must correspond to the machine coordinates for accurate axis position control.
ASD-MDBT0100 and ASD-MDBT0200
ASD-MDBT0100 · Single-battery box. Delta lists it with a battery in the ASDA-A2 catalogue. The enclosure measures 68 × 35 × 22 mm. Check the battery lead required for the compatible single-axis connection.
ASD-MDBT0200 · Dual-battery box. The enclosure measures 72.5 × 45 × 26 mm. Delta shows arrangements in which two compatible drives share one dual box. For a two-axis installation, check each drive and encoder combination, both box connections and the leads specified in the diagram.
A2, A3 and B3 battery connections
ASDA-A2: The AW 3864573700 lead connects the battery box to the battery branch of the absolute encoder cable. The IW 3864811900 lead is for compatible CN8 connections shown in the manual. ASDA-A2 user manual section 12.2.1 shows separate CN2/CN8 examples for single and dual boxes.
ASDA-A3 and ASDA-B3: The standard absolute encoder diagrams in the A3 and B3 manuals show the battery supplying the encoder directly. The feedback cable connects to the drive’s CN2 socket. Before ordering, verify the motor and drive combination, encoder type and connector code.
The single-turn resolution of a rotary encoder describes position within one revolution. Multi-turn data also tracks completed revolutions. During motor selection, check whether the optical or magnetic encoder supports absolute feedback. Where a linear scale also measures load position, read motor and load positions separately when evaluating position accuracy.
Absolute encoder alarms
AL061 indicates low battery voltage. AL060 can appear before absolute position has been established during commissioning or after existing position data has been lost. AL062 indicates that the multi-turn count has exceeded its range. If AL069 appears, check the motor code, encoder type and drive’s absolute mode setting together. The B3 manual explains that AL06A after battery replacement following AL060 requires the absolute origin to be re-established.
Editor’s Note
Photograph the box and cable labels separately. Keep the drive, motor, encoder cable and battery box codes in the same record. On a used box, inspect the battery holder, contacts and connector latch for damage or corrosion.
Record axis position when AL061 appears. If available, back up the drive parameters, absolute position and machine zero offset in the controller. If position data is lost, use these records to verify the new reference.
Plan battery replacement around the model manual. Some Delta procedures call for maintaining drive power to preserve absolute data. The DC bus can remain live in this condition. Qualified staff should carry out maintenance under the machine’s electrical safety and motion-prevention procedures.
Verify machine zero after the alarm clears. If position data was lost, follow the machine’s homing procedure. In a guarded low-speed test, check direction, a known physical reference, the limit switches and electronic gearing where applicable. On coordinated multi-axis systems, verify each axis reference before enabling coordinated motion.
If the fault returns with a new battery, inspect the cable. Use the drive manual to identify whether the alarm concerns battery voltage or encoder communication. If the fault occurs during movement, check the connector, cable carrier, grounding and possible electromagnetic interference.
Delta absolute encoder PDFs
ASDA-A2 catalogue — ASD-MDBT0100 and ASD-MDBT0200 · English, 2023. Battery box dimensions and AW/IW lead codes.
ASDA-A2 — AW/IW battery leads and connection examples · English, 2024. Section 12.1.4 and the following CN2/CN8 diagrams.
ASDA-A3 — absolute encoder battery box installation · English, 2025. Section 10.2.1 and the standard connection diagram.
ASDA-B3 — battery box installation and battery replacement · English, 2025. Sections 10.2.1 and 10.2.2.
Related Delta equipment
ECMA servo motors · ECMA motors with magnetic encoders · Encoder signal converters · Servo STO connections
Delta Servo Modules and Accessories · Used Delta equipment · Delta Servo Manuals archive
External sources · A2 catalogue · A2 manual · A3 manual · B3 manual · Delta absolute position and alarm guidance