Delta ASDA-A2-E

Delta ASDA-A2-E EtherCAT Servo Drives

Delta ASDA-A2-E is an EtherCAT servo drive series for Delta ECMA motors. Its order codes follow the ASD-A2-xxxx-E format. The motion controller sends axis commands over EtherCAT, and the servo drive returns actual position, speed and status. Typical applications include packaging, feeding, cutting and positioning machines with coordinated axes.

220 V and 400 V model codes

220 V class, 100 W–3 kW: ASD-A2-0121-E, ASD-A2-0221-E, ASD-A2-0421-E, ASD-A2-0721-E, ASD-A2-1021-E, ASD-A2-1521-E, ASD-A2-2023-E and ASD-A2-3023-E. Delta also documents the three-phase ASD-A2-4523-E at 4.5 kW, ASD-A2-5523-E at 5.5 kW and ASD-A2-7523-E at 7.5 kW.

400 V class, 400 W–7.5 kW: ASD-A2-0443-E, ASD-A2-0743-E, ASD-A2-1043-E, ASD-A2-1543-E, ASD-A2-2043-E, ASD-A2-3043-E, ASD-A2-4543-E, ASD-A2-5543-E and ASD-A2-7543-E.

The ASD-A2-0421-E and ASD-A2-0443-E are both 400 W drives in different voltage classes. When matching a motor and drive, check the complete ECMA motor code against Delta’s selection table. Confirm the CN2 encoder connection, incremental or absolute feedback, holding brake and servo cables. For a new axis, factor load inertia and peak torque during the machine cycle into motor selection.

EtherCAT, axis modes and connectors

The EtherCAT master controls the drive via CoE / CiA 402. CSP provides cyclic synchronous position control. CSV and CST provide cyclic synchronous velocity and torque control. Profile modes and homing are also supported. For multi-axis synchronisation, verify the drive’s cycle setting against the master’s real-time cycle.

CN6A is the EtherCAT input. CN6B takes the line to the next device. Port order matters in a line EtherCAT topology. CN7 is the digital input expansion connector. With a suitable input configuration, the touch probe function can capture axis position when a registration sensor triggers.

Editor’s Note

Photograph the labels before removing the drive. Record the full drive and motor codes, drive firmware and connector layout. If the old drive can still be read, export its parameter settings. Keep the master project, ESI device description and PDO mapping in the same job folder.

Find where the network stops. If the L/A light is off, start with the cable and the CN6A/CN6B port order. If the drive stays in PRE-OP or SAFE-OP, record the status code reported by the master. For EtherCAT troubleshooting, check the device identity in the ESI, the PDO mapping and the Distributed Clocks settings.

If the network reaches OP and the axis stays still, read the CiA 402 controlword and statusword alongside drive alarms, motion permissions and brake release status. On a vertical axis, STO removes torque. The machine’s brake and safety design provide load holding. Delta’s catalogue states that STO is unavailable on the 4.5–7.5 kW models in the 220 V class.

Measure travel on the first move. During guarded low-speed testing, compare direction and commanded travel with actual motion. Verify homing, travel limits and position scaling. Check for brake drag, backlash and binding before running auto-tune.

If the alarm appears during a fast stop, record the alarm code and the stopping conditions. Energy returned by the load can raise the DC bus voltage during deceleration. Check the deceleration time and the allowed resistance and power rating of the braking resistor for the exact model.

Ask for a loaded test when buying used. Check fan noise, connector damage and alarm history. If intermittent faults coincide with rising motor current, inspect cable routing, electromagnetic interference and grounding. As part of a servo maintenance inspection, watch the drive accelerate and make a controlled stop with a compatible motor.

ASDA-A2-E PDF files

ASDA-A2-E EtherCAT User Manual — English, 2022, 131 pages. CN6/CN7, network states, PDO/SDO, CiA 402, homing and STO.

ASDA-A2-E 220 V and 400 V Technical Catalogue — English, 2021, 8 pages. Power classes, current ratings, dimensions and braking resistor data.

Related Delta equipment

To compare drive series and interfaces on an existing machine, see Delta ASDA-A2, ASDA-A2R and ASDA-A3. For Delta EtherCAT projects, see the AH20EMC-5A motion controller and the DOP-100 HMI for operator displays.

Delta servo drives · Used servo drives · Delta Servo Manuals archive

External references · Delta EtherCAT manual (Inno-Motion) · Delta technical catalogue · Delta model codes and declaration of conformity