Delta DVP64EH00R3
Delta DVP64EH00R3 | DVP-EH3 PLC with 32 inputs and 32 relay outputs
The Delta DVP64EH00R3 is a PLC CPU in the DVP-EH3 series. It runs on 100–240 V AC and provides 32 digital inputs at 24 V DC and 32 relay outputs. In multi-station packaging, conveying and sorting equipment, it reads sensors and sequences valves, indicators and interposing relays.
Inputs, relay outputs and high-speed counting
Inputs X0–X37 use octal addressing. X10 follows X7. Wire the S/S common to match the NPN or PNP interface of the 24 V DC field signals. Use an inductive sensor for metal part position, a photoelectric sensor for product passage, or a suitable capacitive sensor for material detection.
Delta specifies four hardware high-speed counters at up to 200 kHz on suitable inputs. For an incremental encoder, check the A/B signal levels, counter mode and assigned X inputs. The Y0–Y37 relay outputs provide on/off control. For an axis that needs a high-speed pulse command to the drive, see the DVP64EH00T3.
The instruction sheet specifies 2 A per point and 5 A per common for resistive loads. The voltage limit is below 250 V AC or 30 V DC. For a valve or an interposing relay coil, check the inductive load rating and coil suppression separately. Follow the input diagram when sending a dry-contact run command to a variable frequency drive.
The CPU has 30,000 program steps and a 212 mm enclosure width. Record the timer relay settings when replacing the CPU. Check the cabinet drawings for protective grounding and the output-group fuses.
Programming software and cable
Use WPLSoft or ISPSoft. If the existing ladder project was built in WPLSoft, back it up there first. In ISPSoft, select the EH3 CPU family and configure the serial connection in COMMGR. When converting a PLC program, check compilation, I/O addresses and instructions that access expansion modules.
For PC programming, connect the Delta UC-PRG020-12A cable to COM1 RS-232. The cable uses USB at the PC and an 8-pin mini-DIN connector at the PLC. Install the Windows driver and select the COM number shown in Device Manager. A PC with a physical DB9 RS-232 port can also use the UC-MS020-01A.
If an HMI, drive or SCADA system uses Modbus over COM2 RS-485, record the station address, baud rate, parity and ASCII or RTU mode. Delta’s cable guide lists the DVP-FEN01 as an optional Ethernet card for this CPU. The card manual requires EH3 firmware 1.12 or later.
Related Delta models and expansion
The DVP48EH00R3 has 24 inputs and 24 relay outputs. The DVP80EH00R3 has 40 inputs and 40 relay outputs. The DVP64EH00T3 offers the same I/O count with transistor outputs. The DVP64EH00R2 belongs to the earlier EH2 generation. For analog measurement, check the signal range and project settings for the DVP04AD-H3 input module.
Editor’s Note
When buying used, read the full code on the side label. Check that the photo shows the R3 suffix and the condition of the output terminals.
If BAT.LOW is on, back up the program and retentive register values before the planned shutdown and battery service. Follow Delta’s battery and Flash backup procedure.
Isolate power before removal, then photograph the wire numbers at S/S and the output commons. Use those photos when wiring the replacement CPU.
With the machine loads disconnected, test each output group on the bench with a suitable load. When troubleshooting, check the contact response under load as well as the Y LED.
Before returning the machine to production, verify the safety relay and emergency-stop circuit against the cabinet drawings.
Related topics and internal references
Industrial communications · Delta DVP PLC files · Delta DVP-EH3 · Delta DVP PLC series · Delta main page
External references
Delta DVP-EH3 hardware instruction sheet (PDF) · Delta PLC/HMI Cable Selection Guide (Delta download page, section 1.10) · Delta DVP-FEN01 Ethernet card manual (PDF) · Delta WPLSoft and ISPSoft FAQ