Delta DVP48EH00R3
Delta DVP48EH00R3 — 24-input, 24-relay-output PLC
The Delta DVP48EH00R3 is a 48-point PLC CPU from the Delta DVP-EH3 series. It runs from a 100–240 V AC supply and provides 24 digital 24 V DC inputs and 24 relay outputs. With a 30,000-step program capacity, one PLC can sequence multiple stations on packaging, conveyor and assembly lines.
Input addresses, encoders and relay outputs
The built-in PLC I/O is addressed as X0–X27 and Y0–Y27. The addresses are octal, so X10 follows X7 and Y20 follows Y17. When connecting an inductive sensor, a photoelectric sensor or a limit switch, check the signal type and match the S/S input common to the PNP or NPN wiring arrangement.
The hardware sheet specifies 200 kHz input bandwidth for X0, X1, X4, X5, X10, X11, X14 and X15. For an encoder, check the A/B channel assignments, signal level and the counting frequency supported in the selected counter mode. The relay-output CPU can use these inputs for high-speed counting.
For resistive loads, Delta rates the built-in relay contacts at 2 A per point and 5 A per common group. For a contactor or valve coil, check the applicable load rating and suppression. For a servo or stepper drive that needs a high-speed pulse command, check the supported channels on the transistor-output DVP48EH00T3.
Programming software and cable
Use WPLSoft or ISPSoft. For an existing Ladder project, start with the software that matches the source file and check the DVP-EH3 CPU selection. Before making any PLC programming changes, read the current program and save a dated backup. With ISPSoft, configure the serial connection in COMMGR.
Connect the PC to the CPU’s COM1 RS-232 port. Delta’s guide shows the UC-PRG020-12A (2 m) for a PC with USB and the UC-MS030-01A (3 m) for a PC with a serial port. For USB, select the COM number assigned by the cable driver in WPLSoft or COMMGR. See Delta PLC cables for more options.
COM2 and optional communication cards
The CPU’s COM2 is an RS-485 port. For field communications, a Delta DOP-100 HMI or variable frequency drive can exchange data over Modbus on RS-485. For a Modbus RTU project, match the station number, baud rate, parity and register addresses. If the machine has a SCADA connection, keep the address map with the project backup.
The optional DVP-F485 adds an RS-485 interface on COM3. The DVP-FEN01 is a compatible Ethernet function card. When taking over an existing cabinet, record the installed card’s full code and settings.
Related Delta models
The DVP40EH00R3 has 24 inputs and 16 relay outputs. The DVP64EH00R3 has 32 inputs and 32 relay outputs. The DVP80EH00R3 has 40 inputs and 40 relay outputs. For a replacement, compare the X/Y addresses in use, output commons and mounting dimensions. The 40-point CPU’s built-in outputs end at Y17.
Editor’s Note
Check for R3 on the label. When buying used, read the full ordering code in a clear photo. Both 48-point versions share the same case size.
Back up the program and settings together. Save any D register values, recipes or HMI parameters that the machine needs to operate.
Test the contacts under a suitable low-voltage load. With the machine loads disconnected, check that each output switches through its own common group.
Watch the count on encoder-equipped machines. At the bench, check that the program counter follows the direction change correctly.
Check the BAT.LOW indicator and both serial ports. Read the program through COM1 and check that the existing field device replies on COM2. Inspect the terminals and protective grounding before power-up.
Internal references and PDF files
Delta DVP PLC PDF files · DVP hardware, programming and connection documents.
DVP-EH3 series · Delta PLC models · Used Delta equipment
External references
Delta DVP-EH3 instruction sheet · Supply, I/O ratings and port layout.
Delta PLC/HMI cable selection guide · EH3 programming cables and function cards in section 1.10.
Delta DVP PLC and TP HMI catalogue · Ordering codes, program capacity and I/O comparison.