Delta DVP48EH00T3

Delta DVP48EH00T3 Transistor Output PLC

The Delta DVP48EH00T3 is a DVP-EH3 PLC CPU with 24 digital inputs rated at 24 V DC and 24 NPN open-collector transistor outputs. The CPU runs on 100–240 V AC and has a 30k-step program capacity. In packaging, labelling and cutting automation, it can handle material feed, counting and axis positioning in one program.

Digital inputs and 200 kHz high-speed counting

Inputs X0–X27 use octal addressing. X7 is followed by X10. An inductive proximity sensor can detect metal parts, a photoelectric sensor can detect passing products, and a limit switch can report mechanism position. Use the wiring diagram to match the S/S input common to the field device’s PNP or NPN output.

Delta identifies X0/X1, X4/X5, X10/X11 and X14/X15 as the 200 kHz high-speed counter channel pairs. For encoder-based cut length or conveyor distance measurement, check the encoder output type, A/B phase order and selected counting mode.

Transistor outputs and four-axis pulse control

The 24 outputs at Y0–Y27 include four high-speed pulse axes. In pulse-and-direction mode, Y0, Y2, Y4 and Y6 carry pulses, and Y1, Y3, Y5 and Y7 carry the corresponding direction signals. Delta specifies these axes at up to 200 kHz. For position control, check how the servo drive or stepper motor drive accepts NPN open-collector pulses. For auxiliary DC loads, check the output current rating and common-terminal layout. Use a suitable interposing relay and coil suppression where the load calls for them.

Programming software, cable and communication

Use WPLSoft or ISPSoft for PLC programming. Select the DVP-EH3 CPU type in the Ladder project. In ISPSoft, configure the PC-to-PLC connection through COMMGR.

The programming port is 8-pin Mini-DIN COM1 (RS-232). For a USB connection on the PC, use Delta’s UC-PRG020-12A programming cable. Install the driver and select the COM port assigned by Windows. A PC with a DB9 RS-232 port can also use the UC-MS020-01A.

COM2 RS-485 can handle serial communication with an operator panel or drive. On a Modbus link, match the station address, baud rate, parity and ASCII/RTU format. Route serial, encoder and pulse wiring away from motor cables to reduce electrical interference. For Ethernet, use the optional DVP-FEN01 card. Its manual specifies EH3 firmware V1.12 or later.

Editor’s Note

When buying used, read the DVP48EH00T3 label first. Record the T3 suffix, CPU revision and fitted communication card. Check the output terminals for discoloration or looseness.

If the old CPU still runs, back up the program and retained data first. Record the HMI addresses, drive communication settings and the Y outputs assigned to each axis.

If an axis moves in reverse, check the drive’s pulse-and-direction mode and direction signal before editing the program. If encoder counts run backwards, check the A/B channel order.

When the output LED lights, verify transistor switching with a suitable test load. Keep axis movement safely inhibited while measuring the pulse outputs.

If the fault appears when the motor starts, measure the supply under load. Check the output commons, cable shield connections and cabinet grounding together.

Related models and topics

The DVP32EH00T3 and DVP40EH00T3 are transistor-output options with fewer I/O points. For the same 24+24 I/O count with relay outputs, see the DVP48EH00R3. For 32 inputs and 32 transistor outputs, see the DVP64EH00T3.

RS-232, RS-422 and RS-485 compared · Delta DVP PLC series · Used Delta equipment

Internal references and PDF files

OtomasyonAVM Delta DVP PLC Files

External references

Delta DVP-EH3 installation and wiring sheet (PDF, multilingual) · Delta DVP-PLC programming manual (PDF, EN) · Delta PLC/HMI cable selection guide (PDF, EN) · Delta DVP-FEN01 card manual (PDF, EN) · Delta DVP PLC and TP catalogue (PDF, EN)