Delta DVP40EH00R2
Delta DVP40EH00R2 | DVP-EH2 PLC with 24 inputs and 16 relay outputs
The Delta DVP40EH00R2 is a PLC CPU in the DVP-EH2 series. It runs on 100–240 V AC and provides 24 digital inputs at 24 V DC, 16 relay outputs and 16K program steps. In packaging and conveying machines, it can read sensors and sequence valves, indicators and interposing relays.
Inputs, high-speed counters and relay outputs
Inputs X0–X27 use octal addressing. X10 follows X7. Check the manual’s S/S wiring diagram for the installed NPN or PNP signals. An inductive sensor can detect metal part position, a photoelectric sensor can detect a passing product, and a capacitive sensor can detect the presence of suitable materials.
The 40-point EH2 CPU has four hardware high-speed counters at up to 200 kHz. Delta lists X0, X1, X4, X5, X10, X11, X14 and X15 in the high-speed input group. For an incremental encoder, verify signal levels, A/B phases and the selected counter’s input assignment. For example, C251 uses X0 for phase A and X1 for phase B. For applications that send high-speed pulses to a drive, see the DVP40EH00T2.
The Y0–Y17 relay outputs provide on/off control. The instruction sheet specifies 2 A per point and 5 A per common for resistive loads, at working voltages below 250 V AC or up to 30 V DC. Check inductive load limits and coil suppression for valves and interposing relays. Follow the drive input diagram when sending a dry-contact run command to a variable frequency drive.
When replacing the CPU, record any separate timer relay settings. Check the cabinet drawings for output-group fuses and protective grounding.
Programming software and cable
WPLSoft is the first choice for backing up and monitoring an existing EH2 ladder project. In ISPSoft, select the EH2 CPU target in the installed version and configure the serial connection in COMMGR. Keep the original PLC project before converting it. After compiling, review counters, addresses and instructions that access expansion modules.
PC programming uses COM1 RS-232. Delta’s DVPACAB2A30 cable has an 8-pin mini-DIN connector at the PLC and a DB9 connector at the PC. For a USB-only PC, add a compatible USB-to-RS-232 adapter. Install its driver and select the COM number shown in Device Manager.
If an HMI, drive or SCADA system uses Modbus over COM2 RS-485, record the station address, baud rate, parity and ASCII or RTU mode from the existing project.
Related Delta models and expansion
The DVP40EH00T2 has the same 24 inputs and 16 outputs, with transistor outputs. The DVP48EH00R2 has 24 inputs and 24 relay outputs, and the DVP64EH00R2 has 32 inputs and 32 relay outputs. The DVP40EH00R3 has the same I/O count and belongs to the EH3 generation. Compare the project, terminals and expansion modules before migrating. For analog measurement, check the signal range and channel settings of the DVP04AD-H2 module.
Editor’s Note
When buying used, read the full model code on the side label. Ask for a photo showing the R2 suffix and the output terminal condition.
If BAT.LOW is on, back up the program and retentive register values before a planned shutdown. Follow Delta’s battery and Flash procedures.
Once power is isolated, photograph the wire numbers at S/S and the output commons. This is especially useful in cabinets that use different load supplies.
Disconnect machine loads and test the relay groups on the bench with a suitable test load. When troubleshooting the PLC, check the contact response under load as well as the Y LED.
Before returning the machine to production, verify the safety relay and emergency-stop circuit against the cabinet drawings.