Delta DVP40EH00T2
Delta DVP40EH00T2 – EH2 PLC with 24 Inputs and 16 NPN Outputs
The Delta DVP40EH00T2 is a Delta DVP-EH2 PLC CPU powered by 100–240 V AC. It has 24 digital inputs rated at 24 V DC and 16 NPN open-collector transistor outputs. It supports pulse output up to 200 kHz on four axes for machine automation applications such as labeling, cutting and material feeding.
Input and output addresses
Onboard inputs use X0–X27, and outputs use Y0–Y17. Addresses use octal numbering, so X10 follows X7. When wiring an inductive sensor, photoelectric sensor or limit switch, check the signal level and the S/S input common. PNP and NPN sensors require different common wiring. For continuous measurements, consider the difference between analog and digital inputs when selecting a module.
200 kHz counter inputs and pulse outputs
The high-speed counter input pairs are X0/X1, X4/X5, X10/X11 and X14/X15. Delta specifies up to 200 kHz for these inputs. When selecting an incremental encoder, consider the frequency, A/B counting mode and signal level together. For a differential line-driver encoder, use the input schematic to check whether an interface is required.
Delta identifies the high-speed transistor outputs as CH0 (Y0/Y1), CH1 (Y2/Y3), CH2 (Y4) and CH3 (Y6). For position control, check the pulse and direction assignments for the instruction you are using. Match the signal level and control mode of the servo or stepper motor drive. For a Delta ASDA-B2, consult the drive’s wiring diagram. If counts are missed, check protective grounding and possible sources of electromagnetic interference.
WPLSoft, ISPSoft and programming cable
Use WPLSoft or ISPSoft for PLC programming. Select DVP-EH2 as the project target. In ISPSoft, configure the serial connection in COMMGR. Read and save the existing ladder program before making changes.
Connect the PC through COM1 (RS-232, 8-pin mini-DIN) using a DVPACAB230 (3 m) or DVPACAB215 (1.5 m). If the PC has no serial port, add a USB-to-RS-232 adapter. Install the adapter driver and select the COM number assigned by Windows. See Delta PLC cables for other connection options.
COM2 (RS-485) can be used for industrial communication. Record the station number, baud rate and parity on an existing RS-485 Modbus link. For a Modbus RTU connection to SCADA, read known addresses after replacing the CPU to verify the link.
Editor’s Note
Check the label and terminals when buying used. Ask for the full DVP40EH00T2 code and a close-up of the terminals. Delta’s EH2 documents include separate drawings with C commons and UP/ZP terminals. Use the drawing that matches the markings on your unit.
Save the working settings. With the machine in a safe state, save the PLC project, drive parameters and the channel assigned to each axis.
Test the high-speed outputs you plan to use. Check the Y LED and measure the pulse signal with a suitable test load.
Check the encoder in both directions. If the count runs backward, verify the A/B order and the counting mode in the program.
Test the first move at low speed. Under safe commissioning conditions, check direction, homing and limit response.
Related Delta models
The DVP40EH00R2 is the relay version with the same 24 inputs and 16 outputs. The DVP32EH00T2 has 16 inputs and 16 transistor outputs, while the DVP48EH00T2 has 24 inputs and 24 transistor outputs. When considering the later DVP40EH00T3 as a replacement, compare the program, pulse output assignments and expansion cards.
Internal references and PDF files
Delta DVP PLC PDF files · Delta DVP-EH2 installation sheet, 2006 edition (PDF) · Delta DVP PLC series · Used Delta products
External references
Delta DVP-EH2 wiring sheet, 2009 edition (PDF) · Delta DVP PLC programming manual, EH2 table (PDF) · Delta DVP catalogue, EH2 and programming cables (PDF)