Delta DVP48EH00T2

Delta DVP48EH00T2 | PLC with 24 inputs and 24 NPN transistor outputs

The Delta DVP48EH00T2 is a 100–240 V AC main unit in the DVP-EH2 series. It has 24 digital inputs rated at 24 V DC and 24 NPN open-collector transistor outputs. In packaging and conveyor applications, the PLC reads sensors and switches outputs. The CPU runs the machine sequence.

Digital inputs and encoder counting

The built-in PLC inputs and outputs use octal addresses X0–X27 and Y0–Y27. X10 follows X7. When selecting an inductive sensor, identify its PNP or NPN output. Follow the Delta diagram for the sink/source connection to S/S.

For high-speed counting, the X0/X1 and X4/X5 input points are in the 200 kHz class. X10/X11 and X14/X15 are in the 20 kHz class. Check the count mode and input level when using an incremental encoder. An encoder with differential line-driver outputs requires an electrical interface that matches the input.

Transistor outputs and load wiring

Delta lists the DVP48EH00T2’s Y outputs in the standard 10 kHz class. For a servo drive application that requires 200 kHz pulse output, consider a CPU that supports it, such as the DVP40EH00T2. The drive powers the servo motor.

The outputs switch suitable DC loads. When connecting an interface relay or valve coil, check the load current, the common group and coil suppression. Check the DIN rail arrangement and protective grounding during panel installation. A compatible module such as the DVP04AD-H2 can add analog inputs.

Programming software and cables

Use WPLSoft to read and back up the existing ladder program. ISPSoft also supports the EH2 target. Use COMMGR to configure the ISPSoft connection. Confirm the CPU type and instruction support before writing the program to the PLC.

For COM1 (RS-232), use UC-PRG020-12A with a USB-equipped PC or UC-MS020-01A with a native RS-232 port. Install the USB cable driver and select the COM port assigned by Windows. For Modbus over COM2 (RS-485), match the station address and serial settings. Delta PLC cable options

Related Delta models

The DVP48EH00R2 has the same I/O count with relay outputs. The DVP40EH00T2 has 24 inputs, 16 transistor outputs and pulse outputs rated up to 200 kHz. The DVP64EH00T2 has 32 inputs and 32 transistor outputs. The DVP48EH00T3 is an EH3 model with the same I/O count. For an EH3 migration, check the terminal layout, high-speed channel assignments, expansion modules and project.

Editor’s note

When buying used, check the full nameplate code. Compare the T2, R2 and T3 suffixes with the quotation.

Before removal, save the program, the retained data you need and the serial port settings.

On the bench, inspect the BAT.LOW indicator and battery holder. Follow Delta’s procedure for battery service.

If an output LED lights but the load stays off, check the associated common and external DC supply first.

If encoder counts drift, check the input pair, selected count mode and signal level together.