Delta DVP40EH00T3

Delta DVP40EH00T3 – 40 I/O PLC with four-axis pulse output

The Delta DVP40EH00T3 is a Delta DVP-EH3 PLC main unit with a 100–240 V AC supply, 24 digital inputs and 16 NPN open-collector transistor outputs. Its 30,000-step program capacity and up to 200 kHz pulse output on four axes suit labelling, packaging and indexing machines.

Inputs, outputs and high-speed counting

Input addresses run from X0 to X27 and output addresses from Y0 to Y17. Delta numbers X and Y addresses in octal. For inductive sensors and limit switches, check the 24 V DC input circuit and S/S common. The S/S connection depends on the PNP or NPN wiring. The CPU’s AC supply and digital field inputs are separate circuits.

Delta lists X0/X1, X4/X5, X10/X11 and X14/X15 as the input pairs for up to 200 kHz counting. When connecting an incremental encoder, check the A/B counting mode, output circuit and terminal assignment together. For an existing differential line-driver encoder, verify electrical compatibility against the input diagram.

Pulse outputs for servo and stepper drives

Delta’s 40EH3 channel table lists CH0 Y0/Y1, CH1 Y2/Y3, CH2 Y4 and CH3 Y6 as the high-speed outputs. Assign pulse and direction terminals according to the instruction and drive input in use. Check the open-collector input circuit, common connection and frequency limit on the servo drive or stepper motor drive.

If a servo motor travels the wrong distance or moves in the wrong direction, check the pulse count, electronic gearing and mechanical transmission together. If motion is steady at low speed and erratic at high speed, measure the pulse signal at the drive input.

Programming software, cable and communications

Use WPLSoft for existing ladder projects. ISPSoft also supports PLC programming for this family. Select the DVP-EH3 target in ISPSoft and the serial channel created in COMMGR. Keep a copy of the original project before conversion.

COM1 RS-232 uses an 8-pin mini-DIN connector. Delta’s EH3 cable guide lists UC-PRG020-12A for a USB connection and UC-MS020-01A for a PC with a physical RS-232 port. Install the USB cable driver and select the COM port assigned by Windows. See Delta PLC programming cables for more options.

COM2 RS-485 is the built-in field communications port. On an RS-485 Modbus line, match ASCII or RTU mode, station address and serial settings across devices. For an Ethernet installation, verify CPU hardware and firmware compatibility with the DVP-FEN01 card.

Related Delta EH3 models

The DVP40EH00R3 has the same 24 inputs and 16 outputs with relay switching. The DVP32EH00T3 has 16 inputs and 16 transistor outputs. Check its manufacturing revision for the pulse channel count. The DVP48EH00T3 has 24 inputs and 24 transistor outputs. The DVP64EH00T3 has 32 inputs and 32 transistor outputs. Before replacing a CPU, compare terminal assignments, expansion cards and the software target.

Editor’s Note

Look for T3 on the label. When buying used, ask for a photo of the full model code and output terminals. The relay-output R3 cannot take over pulse control on the machine.

Measure the pulses. Even when the output LEDs look normal, test all four channels individually with a suitable load and an oscilloscope.

Test counting at the bench. Use a known-good encoder and count in both directions. Compare the direction and pulse count with the expected values.

Back up the program before clearing it. Save retained data, axis parameters and serial settings as well. Check how the machine homes after power returns.

If trouble starts when the motor runs, check grounding and cable routing. Measure the signal at the drive input when checking for electromagnetic interference. If an output may be damaged, check load current, the common terminal and the fuse.

Internal references and PDFs

Delta DVP PLC files

Related topics · Delta DVP PLC series · Delta PLC · Used Delta equipment

External references

Delta DVP-EH3 instruction sheet, 5012613904-04H3 · Delta DVP-PLC programming manual, §2 · Delta PLC/HMI cable selection guide, EH3