Delta DVP32EH00T3
Delta DVP32EH00T3 PLC | 16 Inputs, 16 Transistor Outputs
The Delta DVP32EH00T3 is a 100–240 V AC PLC CPU in the DVP-EH3 series. It has 16 digital inputs at 24 V DC and 16 NPN open-collector transistor outputs. In a labelling or cutting machine, it can read inductive sensors and photoelectric sensors and control positioning axes from the same program.
Digital I/O and 200 kHz pulse channels
The built-in inputs and outputs use octal addresses X0–X17 and Y0–Y17. For PNP or NPN sensors, check the S/S common against Delta’s sink/source diagram. Use DC loads suitable for the open-collector Y outputs. For continuous measurements such as pressure, check the analog and digital input requirements and select a suitable expansion module.
The Delta catalogue lists 30,000 program steps and 12,000 data-register words for EH3.
The four 200 kHz-class counter input pairs are X0/X1, X4/X5, X10/X11 and X14/X15. When connecting an incremental encoder, check the A/B signal levels and the frequency limit for the selected counting mode. For high-speed pulse output, Delta’s earlier catalogue shows two 200 kHz axes. Its later catalogue specifies four axes on units produced after 2014. On the upgraded 32EH3, the instruction sheet lists Y0, Y2, Y4 and Y6 as 200 kHz outputs.
For pulse/direction servo motor control, follow the servo drive’s input wiring diagram. On a Delta ASDA-A2, for example, verify the open-collector input wiring and common reference. If you use a differential line-driver encoder, check its output level and the type of input it will connect to.
Programming software and cable
Use WPLSoft to open the existing Ladder project and read the PLC program back to the PC for a backup. With ISPSoft, select the DVP-EH3 target and start the serial driver in COMMGR. For the programming connection, check the Windows COM port and the PLC’s current serial settings.
COM1 is the PLC’s RS-232 programming port. Delta lists UC-PRG020-12A for a USB-equipped PC. Install its driver and select the assigned COM port. UC-MS030-01A is also an option for a PC with a serial port. See Delta PLC cables for other connection options.
COM2 is an RS-485 port for industrial communications. For Modbus RTU, match the station address, baud rate, parity and stop bits at both ends. For Ethernet, see the optional DVP-FEN01 Ethernet card that Delta lists for this CPU and check the installed hardware revision.
Related Delta models
DVP32EH00R3 has the same I/O count and relay outputs. DVP32EH00M3 offers high-speed differential pulse outputs. DVP32EH00T3-L supports high-speed left-side expansion. DVP40EH00T3 provides 24 inputs and 16 transistor outputs. Compare terminal layouts, axes and installed cards before swapping CPUs.
Editor’s Note
When buying used, ask for a photo of the side label. If you need four axes, confirm the production details and ask for a test of each channel.
Back up the program and required parameters through COM1 first. Record the part number of any installed communication card.
Check the RUN, ERROR and BAT.LOW indicators. If the battery warning is on, save a backup before following Delta’s battery procedure.
When the output LED lights, verify the pulses with a suitable instrument. Disable machine motion for the high-speed output test.
If the count becomes erratic when the drive starts, inspect the encoder cable route, sources of electromagnetic interference and cabinet grounding.
Related topics, internal references and PDF files
Delta DVP PLC files · Delta DVP-EH3 series · Delta DVP-FEN01
External references
Delta EH3 instruction sheet (EN and Chinese PDF) · Delta DVP catalogue and production note (EN PDF) · 2014 Delta DVP catalogue (EN PDF) · Delta PLC/HMI Cable Selection Guide (EN PDF, section 1.10) · Delta DVP-PLC Programming Manual (EN)