Delta DVP202LC-SL

Delta DVP202LC-SL Two-Channel Load Cell Weighing Module

The Delta DVP202LC-SL is a two-channel, high-speed weighing module that mounts on the left of a compatible Delta DVP PLC CPU. CH1 and CH2 accept millivolt signals from 4- or 6-wire load cells. Each channel has its own sensitivity, filter and calibration settings. One PLC can monitor two filling stations, for example, or a hopper scale and a checkweigher.

Weighing inputs and load cell wiring

The module runs on 24 V DC (20.4–28.8 V DC), supplies nominal 5 V DC bridge excitation and accepts ±200 mV DC input signals. The A/D converter has 24-bit resolution and the module reports weight as 32-bit data. The data sheet lists nine response-time settings from 2.5 to 400 ms per channel. PLC scan time, filtering and mechanical settling also affect the response of a filling line.

A strain gauge load cell uses a Wheatstone bridge to turn small changes in shape under load into a voltage signal. Match the channel setting to the sensor’s mV/V rating. For example, 5 V excitation on a 2 mV/V cell produces about 10 mV of signal change at rated load. The guides to how load cells work and selecting weighing sensors explain signal level and capacity in more detail.

EXC+/EXC− excite the bridge, SIG+/SIG− carry the measurement signal and SEN+/SEN− sense the bridge excitation voltage. Connect the sense leads of a six-wire cell to the SEN terminals. For four-wire cells, jumper each SEN terminal to its matching EXC terminal as shown in Delta’s diagram. If several cells share a channel in parallel, Delta specifies a combined impedance above 40 Ω.

PLC compatibility, software and programming cable

Use a DVP-SA2, DVP-SX2, DVP-SE or DVP-SV2 CPU model with the left-side high-speed expansion port. The DVP12SA211R and DVP12SE11R are examples. Check the full CPU order code and firmware version. The left-side module nearest the CPU is addressed as K100. The DVP202LC-SL returns its model ID, H’5206, in CR#0.

Use WPLSoft or ISPSoft for the PLC program. For example, the DVP12SA211R can connect through its 8-pin mini-DIN COM1 RS-232 port using a Delta UC-PRG020-12A USB-to-RS-232 cable. The DVP12SE11R also supports an Ethernet connection. See Delta PLC programming cables for other CPU ports. For LCSoft setup and calibration, connect the PC to the weighing module’s own COM1 RS-232 port. In stand-alone operation, a host can read the module over Modbus through COM2 RS-485.

The PLC reads CH1 weight from CR#12–13 and CH2 weight from CR#14–15, using two words per channel. Use the CR#51 status bits to determine when the weight has stabilized before acting on it. See integrating weighing into production for how these values and status signals fit into a machine’s control sequence.

Zero, calibration and tare

Calibrate each channel with its own scale assembly. For two-point calibration, capture the zero point with an empty, stable platform, then use a known reference weight to establish the scale factor. With a PLC scale of 1 kg = 1000, one count represents 1 gram. Check an intermediate weight, save the settings to the module’s nonvolatile memory and verify them after cycling power. Tare subtracts the container weight from the gross reading to give the net weight. See weight measurement and the weighing FAQ for the underlying concepts.

Editor’s Note

When buying a used DVP202LC-SL, check the label, the left-side expansion connector and the terminals for both channels. Confirm that all terminal blocks are included.

On the bench, move a known-good load cell from CH1 to CH2. On both channels, check zero return, repeatability under a known load and channel status.

If the reading fluctuates, check that the platform moves freely, verify the bridge excitation and inspect the shielded cable routing. Keep the signal cable away from drive and motor wiring.

Heavier filtering can increase settling time. Test the switch from coarse to fine filling in a real cycle, when material may still fall after the cutoff command.

Record channel settings and PLC/HMI scaling before replacing a module. Verify the replacement with a reference weight and check the net reading after taring the container.

Related models and topics

See the DVP201LC-SL for single-channel weighing and the DVP211LC-SL for applications that need one weighing channel with 2 digital inputs, 4 digital outputs and 1 analog output. Related models include the DVP01LC-SL and DVP02LC-SL. Compare control registers, terminals and response time before replacing a module.

Delta DVP Slim weighing modules · Delta DVP expansion units · Delta PLC models · Used Delta automation equipment

PDFs and wiring diagrams · Delta DVP PLC PDF files

External references · Delta Load Cell Module Instruction Sheet (2023, EN/TR) · Delta DVP201/202/211LC-SL Operation Manual (2019, EN) · Delta DVP Series Module Manual, Chapter 12 (2026, EN)