Delta DVP02LC-SL

Delta DVP02LC-SL — 2-channel load cell weighing module

The Delta DVP02LC-SL is a weighing module with two independent load cell inputs for the left-side expansion bus of compatible Delta DVP PLCs. CH1 and CH2 read 4-wire or 6-wire strain-gauge load cells. The PLC can use the two readings for separate weighing points on tanks, hoppers or filling machines.

A load cell’s mV/V rating expresses its signal at rated load relative to the excitation voltage. A 2 mV/V cell excited at 5 V produces approximately 10 mV differential output at rated load. See how load cells work and the guide to load cell types for mechanical mounting and electrical selection.

Supply, sensitivity and wiring

The module uses a 24 V DC supply (20.4–28.8 V DC), consumes 3 W and accepts a ±40 mV DC input signal. Load cell excitation is nominally 5 V DC. Select the 1, 2, 4 or 6 mV/V range shared by both channels in CR#2. The default is 2 mV/V. Weight data read by the PLC are signed 16-bit values.

Each channel uses EXC+/EXC− for excitation, SIG+/SIG− for measurement, SEN+/SEN− for remote sensing and SHD for the shield. For a 4-wire cell, jumper EXC+ to SEN+ and EXC− to SEN− at the module. A 6-wire cell has separate sense leads. Verify each wire colour against the cell manufacturer’s drawing.

PLC compatibility, software and weight registers

The Delta manual lists left-side expansion support for DVP-SV, DVP-SA2, DVP-SX2 and DVP-EH2-L families. Check the exact CPU model before fitting the module. Left-side modules use numbers 100–107. The module closest to the CPU is 100. PLC programming takes place on the host CPU with WPLSoft or ISPSoft, subject to CPU support. For compatible 8-pin RS-232 CPU ports, see the UC-PRG020-12A and other DVP programming cables.

CR#12 / CR#13 hold the CH1 and CH2 average weights, while CR#14 / CR#15 hold their current weights. With the module first on the left-side bus, FROM K100 K14 D100 K2 reads two current values into D100–D101. Use TO to write settings. CR#4 holds the arithmetic mean of the channels. To obtain a total, scale both readings to the same unit and add them in the PLC.

The module also offers serial communication through RS-232 and RS-485. Delta’s PC setup example connects to the module over RS-232. See the Delta LCSoft page for model and software version support. For Modbus RTU or ASCII, the average weight addresses are 0x100C / 0x100D and current weight addresses are 0x100E / 0x100F.

Calibration, tare and saving

Capture the zero point with the weighing assembly empty and stable. Apply a known reference weight within the cell’s capacity and enter the second point. For example, 1 kg can be scaled as 1000 g. Use CR#33 and CR#34 for the CH1 and CH2 reference values and CR#26 for the calibration command. Write H5678 to CR#41 to save the finished calibration to non-volatile memory. HFFFF indicates that saving completed. CR#6 captures tare, and CR#7 selects gross or net display.

Editor’s Note

On a used unit, inspect the terminal blocks for both channels, the side expansion connector and the 24 V DC input. Check the supply voltage first if the L.V LED is on.

If the reading drifts with a fixed load, check for mechanical binding, cable pull on the weighing structure and nearby drive wiring.

Switch off power, then use a multimeter to check sense jumpers and cable continuity. Identify excitation and signal leads from the cell manufacturer’s drawing.

Run zero and reference-weight tests on both channels. If the current value fluctuates, compare it with the average and the stable-weight bit in CR#50.

Tare sets an empty container to zero net weight. If the same reference weight produces different readings, check calibration and mechanical mounting first.

Related topics and modules

DVP01LC-SL single channel · DVP201LC-SL single channel · DVP202LC-SL dual channel · DVP211LC-SL model with additional I/O

DVP Slim load cell modules · DVP expansion modules · Used Delta PLCs · Delta main page

PDF files and manuals

Delta DVP PLC PDF files

External references · Delta DVP Module Manual, chapter 12 (EN) · DVP02LC-SL operation manual (EN) · DVP02LC-SL wiring sheet (includes TR/EN)