Delta DVP32ES00T2
Delta DVP32ES00T2 | DVP-ES PLC with 16 inputs and 16 transistor outputs
The Delta DVP32ES00T2 is a compact PLC CPU from the original Delta DVP-ES series. It runs on 100–240 V AC and provides 16 digital inputs at 24 V DC and 16 NPN open-collector transistor outputs. It can read sensors and sequence outputs in conveyors, packaging machines and sorting equipment.
Technical specifications and field wiring
Inputs X0–X17 use octal addressing. X10 follows X7. The inputs support sink or source wiring. Check the S/S common against the manual’s wiring diagram for the installed NPN or PNP sensor type. A machine can use an inductive sensor for metal parts, a photoelectric sensor for passing products, or a capacitive sensor for presence detection where the material suits it. For an incremental encoder, check the signal type and count rate against the selected input.
The Y0–Y17 NPN outputs sink load current to 0 V when active. The output voltage limit is 30 V DC. Delta’s instruction sheet specifies 0.30 A at 40 °C, 0.20 A at 45 °C, 0.15 A at 50 °C and 0.10 A at 55 °C per point, with 2 A maximum per common. Check current draw and coil suppression when selecting a DC valve or an interposing relay. For a digital run command to a variable frequency drive, check the drive’s input type and common terminal.
The CPU has 3,792 program steps, built-in EEPROM, COM1 RS-232 and COM2 RS-485. If the cabinet has a separate timer relay, record its setting as part of the CPU replacement. Check the cabinet drawings for protective grounding and fuse details.
Programming software and cable
WPLSoft is the first choice for reading, backing up and monitoring an existing DVP-ES ladder project. If using ISPSoft, verify that the installed version offers the original ES CPU target and select the serial channel in COMMGR. Keep the original WPLSoft file before converting it. Compile the converted PLC program and review its addresses and instructions.
Use a Delta UC-PRG020-12A cable from the PC’s USB port to the PLC’s COM1 RS-232 port with the 8-pin mini-DIN connector. After installing the Windows driver, select the COM number shown in Device Manager. A PC with a physical DB9 RS-232 port can also use the UC-MS020-01A. That serial cable requires a separate USB-to-RS-232 adapter on a USB-only PC.
If an HMI, drive or SCADA system uses an industrial communications link on COM2 RS-485, record the station address, baud rate and parity from the existing project.
Related Delta models
The DVP32ES00R2 has the same 16 inputs and 16 outputs, with relay outputs. The DVP24ES00T2 has 16 inputs and 8 transistor outputs. The DVP40ES00T2 has 24 inputs and 16 transistor outputs. The DVP32ES200T has 16 inputs and 16 transistor outputs and belongs to the ES2 generation. Compare the terminal layout, expansion modules and program compatibility before migrating.
Editor’s Note
When buying used, ask to see the side label and the terminals. Check that the full code ends in T2.
If the original unit still works, back up the program and communications settings first. Keep a separate copy of the original project file if you have it.
Once power is isolated, photograph the S/S and output commons before removing wires. This makes it easier to match wire numbers to the terminal diagram.
On the bench, monitor inputs one at a time with machine loads disconnected. Use a suitable DC test load for the output groups. When troubleshooting the PLC, check the terminal and load response as well as the Y LED.
Before returning the machine to service, verify the safety relay and emergency-stop circuit against the cabinet drawings.
Related topics
Modbus over RS-485 · Modbus ASCII · Modbus RTU
Internal references and PDF files
Delta DVP PLC files · DVP-ES/EX hardware instruction sheet (English PDF)
Delta DVP-ES · Delta DVP PLC series · Delta main page
External references
Delta PLC/HMI Cable Selection Guide (PDF, section 1.2) · Delta DVP-PLC Application Manual (Programming, PDF) · Delta WPLSoft and ISPSoft FAQ