Delta DVP32ES200T

Delta DVP32ES200T – ES2 PLC with 16 Inputs and 16 Transistor Outputs

The Delta DVP32ES200T is a Delta DVP-ES2 PLC base unit powered by 100–240 V AC. It provides 16 digital inputs, 16 transistor outputs and a 16K-step program capacity. It suits machines with multiple sensors, pushbuttons and sequence control requirements. Use suitable Delta DVP expansion modules for additional signals.

24 V DC inputs and two output groups

Inputs X0–X17 use octal addressing. These are 24 V DC sink/source inputs. Check the S/S input common against the panel drawing when connecting PNP or NPN sensors. Outputs Y0–Y7 use UP0/ZP0, while Y10–Y17 use UP1/ZP1. Check the external 24 V DC auxiliary supply for the output stage against Delta’s wiring diagram. The transistor outputs switch loads within the specified 5–30 V DC range.

Encoders and high-speed pulse outputs

Delta’s ES200 table gives a maximum input frequency of 100 kHz for X0 and X2. For an incremental encoder, also check the A/B phase wiring and the frequency limit of the selected counter mode. Transistor outputs Y0 and Y2 are rated at up to 100 kHz. Y1 and Y3 are rated at up to 10 kHz. For a pulse-and-direction servo drive, match the output address and electrical interface to the drive input.

Programming software, cable and Modbus

Use WPLSoft or ISPSoft to program the PLC. Select a CPU type that supports DVP-ES2. For COM1 RS-232, Delta recommends the UC-MS030-01A DB9-to-8-pin-mini-DIN cable. The mini-DIN connection on Delta’s UC-PRG020-12A cable can be used with a USB-equipped PC. In ISPSoft, select the correct COM port in COMMGR. Use COM2 and COM3 for RS-485 Modbus ASCII/RTU. For example, an operator panel can use one serial bus while the PLC reads variable-frequency drive status over the other.

Editor’s Note

Check the 200T suffix on the nameplate. The 211T has the same I/O counts and uses a 24 V DC main supply.

With the panel de-energized, inspect both UP/ZP groups and the terminal screws. Loads on a group may stay off if its auxiliary supply is missing.

Test both output groups with a suitable DC load. The LED shows the command. A measurement across the load shows whether the output switches.

For pulse applications, test Y0 or Y2 near the operating frequency. Check the count direction on machines with encoders.

Before replacement, back up the ladder program, I/O assignments, Modbus addresses and serial port parameters.

Related models and topics

The DVP32ES200R has the same I/O counts with relay outputs. The DVP32ES211T uses a 24 V DC supply. The DVP32ES200TC adds CANopen, while the DVP32ES200TE is the Ethernet variant. For new panels, assess Derell Series B PLCs against the project’s I/O and software requirements.

Used Delta automation equipment · Delta PLC · Delta DVP PLC series · Delta DVP PLC files

External references

Delta ES2 instruction sheet, 32ES2-T terminal layout · Delta PLC/HMI cable selection guide, ES2/EX2 · Delta ES2 programming manual (2025, EN)