Delta DVP16EH00T3
Delta DVP16EH00T3 | DVP-EH3 PLC with 8 inputs and 8 transistor outputs
The Delta DVP16EH00T3 is a PLC CPU from the DVP-EH3 series. It runs on 100–240 V AC and provides 8 digital inputs at 24 V DC, 8 NPN open-collector transistor outputs and 30,000 program steps. It can command up to two pulse-controlled axes in labeling, dispensing and cut-to-length machines with modest I/O needs.
Inputs, high-speed counting and pulse outputs
Wire the S/S common for inputs X0–X7 to match the NPN or PNP field signals. An inductive sensor can detect a reference position and a photoelectric sensor can detect a passing product. For an incremental encoder, check the counter mode and the X0, X1, X4 and X5 terminals listed in Delta’s 200 kHz group. The catalogue specifies two 200 kHz high-speed counters for this model.
Y0 and Y2 provide pulse outputs of up to 200 kHz for two axes. Direction output assignment depends on the positioning instruction and the drive’s pulse mode. Use the drive wiring diagram to verify that the servo or stepper motor drive accepts NPN open-collector signals at the intended voltage.
The Y0–Y7 outputs operate at 5–30 V DC. The instruction sheet specifies a 0.5 A resistive load limit per point. For valves or interposing relay coils, check the inductive load rating and coil suppression. For an on/off command to a variable frequency drive, check the input type and common terminal. Keep the cabinet’s grounding and fuse details with the replacement records.
Programming software and cable
Use WPLSoft or ISPSoft. If the existing ladder project was written in WPLSoft, back it up there first. In ISPSoft, select the EH3 CPU family and the serial channel in COMMGR. After converting and compiling a PLC program, review the positioning instructions and axis addresses.
The programming port is COM1 RS-232. For a USB-equipped PC, use a UC-PRG020-12A cable with its 8-pin mini-DIN connector at the PLC. Install the cable driver and select the COM number shown in Windows Device Manager. A PC with a DB9 RS-232 port can use the UC-MS020-01A.
If an HMI, drive or SCADA system uses Modbus over COM2 RS-485, record the station address, baud rate, parity and ASCII or RTU mode. If a third serial port is needed, Delta lists the DVP-F485 as an optional RS-485 card for this model.
Related Delta models
The DVP16EH00R3 also has 8 inputs and 8 outputs, with relay outputs. The DVP20EH00T3 has 12 inputs and 8 transistor outputs. The DVP32EH00T3 has 16 inputs and 16 transistor outputs, and the DVP40EH00T3 has 24 inputs and 16 transistor outputs. Compare terminal layouts and axis assignments when changing the CPU.
Editor’s Note
When buying used, ask for a photo showing the T3 suffix and the condition of the output terminals.
If BAT.LOW is on, back up the program, retentive registers and axis settings before the planned shutdown. Follow Delta’s battery service procedure.
Once power is isolated, photograph the wire numbers at S/S and the output commons before removing the CPU.
For a two-axis setup, test Y0 and Y2 individually on the bench. When troubleshooting the PLC, check the output LED and verify the pulse signal with suitable test equipment.
Before returning the machine to production, check the safety relay, emergency stop and axis reference sensors against the cabinet drawings.