Delta DVP16EH00R3

Delta DVP16EH00R3 Relay Output PLC

The Delta DVP16EH00R3 is a DVP-EH3 PLC CPU with 8 digital inputs and 8 relay outputs. It takes a 100–240 V AC supply and has a 30k-step program capacity. It suits automation tasks with a small number of field signals and a need for high-speed counting. On a conveyor, for example, it can track travel with an encoder and switch a diverter valve control circuit when a product is detected.

Digital inputs and high-speed counting

Inputs X0–X7 can read an inductive proximity sensor, a photoelectric sensor or an end-of-travel limit switch. The standard input circuit is in the 24 V DC class. Use Delta’s wiring diagram to match the S/S input common to the sensor’s PNP or NPN output.

Delta identifies X0/X1 and X4/X5 as the two high-speed counter input pairs rated at up to 200 kHz. Check the encoder output type, A/B phase order and selected counting mode. When measuring cut length, move the material through a known distance and compare it with the pulse count reported by the PLC.

Relay outputs and common terminals

The terminal diagram identifies C0–C7 as the commons for relay outputs Y0–Y7. The outputs can switch an interposing relay, a contactor control circuit or a panel indicator. Delta specifies 2 A per output for resistive loads and a relay response time of about 10 ms. Check the separate ratings and inrush current for coil and lamp loads. Select the fuse and coil suppression for the load circuit.

Programming software, cable and communication

Use WPLSoft or ISPSoft for PLC programming. Select the DVP-EH3 CPU type in the Ladder project. In ISPSoft, configure the communication channel through COMMGR.

The PLC connects through its 8-pin Mini-DIN COM1 (RS-232) port. For a USB connection on the PC, use Delta’s UC-PRG020-12A programming cable. Install the driver and select the COM number assigned by Windows. A PC with a DB9 RS-232 port can use UC-MS020-01A.

COM2 RS-485 can handle serial communication with an operator panel or drive. On a Modbus link, match the station address, baud rate, parity and ASCII/RTU format. Route encoder and serial cables away from motor wiring to reduce electrical interference.

Editor’s Note

When buying used, check the full DVP16EH00R3 code on the label. Look for loose terminals, discoloration or heat marks around Y0–Y7 and C0–C7.

If the original CPU still runs, back up the program, retained D register values and serial settings. If BAT.LOW is on, save the existing data before servicing the battery.

If encoder counts are intermittent, start with the X0/X1 or X4/X5 pair, A/B channel order and counting mode. If the fault only appears at higher speeds, check the signal and wiring as well.

On the bench, disconnect the machine loads and test the outputs one by one with a suitable low-voltage test load. If the LED lights and the load stays off, check the common supply and relay contact separately.

If the PLC resets when a contactor pulls in, measure the supply under load. Check coil suppression and cabinet grounding.

Related models and topics

For high-speed pulse outputs with the same 8+8 I/O count, see the transistor-output DVP16EH00T3. Within the relay-output range, the DVP20EH00R3 has 12 inputs and 8 outputs, the DVP32EH00R3 has 16 inputs and 16 outputs, and the DVP48EH00R3 has 24 inputs and 24 outputs. Compare output type, terminal layout and installed cards before replacing a CPU.

RS-232, RS-422 and RS-485 compared · Delta DVP PLC series · Used Delta equipment

Internal references and PDF files

OtomasyonAVM Delta DVP PLC Files

External references

Delta DVP-EH3 installation and wiring sheet (PDF, multilingual) · Delta DVP-PLC programming manual (PDF, EN) · Delta PLC/HMI cable selection guide (PDF, EN) · Delta DVP PLC and TP catalogue (PDF, EN)