The Delta DVP20EH00T3 is a 100–240 V AC PLC main unit in the Delta DVP-EH3 series. It has 12 digital inputs rated at 24 V DC and 8 NPN open-collector transistor outputs. It reads sensors and sends high-speed pulse commands to compatible drives on two axes in applications such as labeling, cut-to-length and indexing.
Digital inputs and encoder wiring
The inputs use octal addresses X0–X7 and X10–X13. The S/S common connection sets the input circuit for sinking or sourcing. Check the PNP or NPN signal type against the panel diagram. When wiring an inductive sensor or limit switch, verify the input voltage and common connection together.
The hardware sheet specifies 200 kHz input bandwidth for X0, X1, X4 and X5, and 20 kHz for X10 and X11. When connecting an incremental encoder, check the A/B signal type, high-speed counter mode and frequency limit for that mode. The encoder’s pulse count and maximum shaft speed determine the required counting capacity.
Transistor outputs and two-axis pulse control
Y0 and Y2 provide high-speed pulse output up to 200 kHz. Delta’s programming manual identifies the first pulse group as CH0 (Y0/Y1) and the second as CH1 (Y2/Y3). Check the drive’s pulse format and terminal assignments against the motion instruction in use. When connecting a servo drive or a drive for a stepper motor, match the input voltage, current and common connection.
The Y0–Y7 output circuit operates at 5–30 V DC. Delta’s table lists resistive-load limits of 0.5 A per point and 4 A per COM. For pulse inputs, follow the drive’s own electrical requirements. Use a suitable flyback diode or suppressor for DC coils and a suitably rated interposing relay for AC coil control.
Programming software and cable
Program the DVP20EH00T3 with WPLSoft or ISPSoft. Select the DVP-EH3 target in the project. For an ISPSoft serial connection, configure and start the channel in COMMGR and select the same channel in ISPSoft. On an existing machine, check the source project and CPU firmware first. See the guides to ladder diagrams and PLC programming for help reading the program.
The computer connects to the PLC through its 8-pin mini-DIN COM1 / RS-232 port. Use UC-PRG020-12A for a USB-equipped PC or UC-MS020-01A for a PC with a physical RS-232 port. Install the USB cable driver and select the COM number assigned by Windows. See Delta PLC cables and the guide to RS-232, RS-422 and RS-485 when choosing a cable.
Field communication and expansion
COM2 / RS-485 can communicate with an HMI or drive. For Modbus over RS-485, match the station address, baud rate, parity and frame format. If the project uses Modbus RTU, select the same protocol on the HMI or drive. For projects that require an Ethernet card, select a CPU from Delta’s DVP-FEN01 compatibility list. It includes the DVP32EH00T3 and selected larger models.
Program capacity is 30 k steps. Compatible expansion modules bring total capacity up to 512 I/O points. For a 0–10 V or 4–20 mA measurement signal, consider a suitable module such as DVP04AD-H3. Check the channel settings and the difference between analog and digital inputs before choosing an interface.
Editor’s Note
Get a close-up of the label. When buying used, ask for photos showing the 00T3 suffix, output terminals and any installed cards.
Measure the pulse at the drive input. An output LED gives no reading of the signal level at the drive. Safely prevent machine motion before checking Y0 and Y2 with suitable test equipment.
Check each axis separately. Verify the pulse group and direction first. Record the existing output assignments before changing cables or replacing the CPU.
Back up before switching off. If BAT.LOW is lit, save the program, retained values and serial port settings. Follow Delta’s battery procedure.
If counts drop at higher speeds, check the assigned X terminals, the input filter and the encoder cable’s proximity to motor wiring. X10 and X11 are rated at 20 kHz on this model.
Internal References | Related Delta Models
The DVP20EH00R3 has the same 12 inputs and 8 outputs with relay switching. The DVP16EH00T3 has 8 inputs and 8 transistor outputs. For more onboard I/O, see the DVP32EH00T3 and DVP40EH00T3. Compare terminal layouts, program instructions and high-speed output assignments before changing models.
Related Topics
The axis load and positioning requirements guide servo or stepper selection. Verify the home position and travel limits before running the automatic cycle. For panel wiring and emergency stops, see the guides to grounding and safety relays.
OtomasyonAVM PDF and Series Links
Delta DVP PLC files · All Delta DVP PLC series · Used Delta models
External References
Delta DVP-EH3 hardware and terminal sheet (PDF) · Delta DVP-PLC application manual, programming (EN, PDF) · Delta PLC/HMI cable selection guide, section 1.10 (EN, PDF)