Delta Servo Operator Panel Cables
Delta Servo Operator Panel Cables
The Delta ASDBCADK0001 cable connects an ASDA-B servo drive to an ASD-PU-01A or ASD-PU-01B digital keypad. Delta’s drawing specifies an 8-pin Mini-DIN connector at the drive end and a cable length of 1,000 ±15 mm. The keypad is used to monitor the servo system, read alarms and access drive parameters.
Cable part numbers and endpoints
ASDBCADK0001 · ASDA-B CN3 ↔ ASD-PU keypad.
ASDBCACK0001 · ASD-PU keypad ↔ PC.
DVPACAB2A30 · ASDA-B CN3 ↔ PC. This is the part number listed in Delta’s June 2009 manual.
If the PC has no serial port, select the USB converter using the PC connection diagram. For the machine’s touchscreen HMI, consult its port and cable table. The motor encoder and its feedback signals use the drive’s CN2 connection.
Keypad communication settings
On the ASD-PU keypad, P8-05 sets the drive address, P8-06 sets the baud rate, P8-07 sets the protocol and data format, and P8-08 selects RS-232 or RS-485. For Modbus ASCII or Modbus RTU, compare the address, baud rate and data format at both ends. The Modbus FAQ covers common serial communication questions.
Editor’s Note
1. Show both cable ends when ordering. Ask for the keypad’s rear label, the complete drive code and photos of both plugs. Inspect the Mini-DIN alignment key and the latch at the keypad end.
2. Check for ALE 41 if the keypad powers up without drive data. This code indicates a receive timeout. With the system safely isolated and the cable disconnected at both ends, use a multimeter to check continuity against the manual’s diagram. Record which cable was used in the maintenance log.
3. Investigate ALE 42 and ALE 43 separately. ALE 42 indicates a checksum error during reception. ALE 43 indicates a response address mismatch. For ALE 43, check P8-05 in particular. Record the existing values before changing any settings.
4. Check cable routing if the fault appears during motion or contactor switching. Check grounding and separation of signal and power wiring against the panel schematic. See the articles on EMI filters and EMC emissions for more on interference.
5. Start a used-keypad test in read mode. Verify the status display, keys and parameter reading. If testing JOG from the keypad, check travel direction and limit switches under the machine’s test procedure. Back up the drive parameters before adjusting position, speed and torque settings or running auto-tuning.
Cable drawing and technical document
Delta ASDA-B — Operator Panel Cable Drawing (PDF) · English, June 2009, 321 pages. PDF page 314 shows the ASDBCADK0001 drawing. See page 315 for the other cables, page 52 for CN3 and pages 265–266 for keypad communication faults.
Open the cable drawing in the currently published ASDA-B manual
Related Delta equipment
Delta ASDA-B · ASDA-AB · ASDA-B2 · ASDA-A3 · Delta HMI manuals
Servo cables · Communication units · Servo I/O connections · Encoder connectors · Power connectors
Delta Servo Modules and Accessories · Used Servo Drives · Delta Servo Manuals