Delta ASDA-AB

Delta ASDA-AB Servo Drive

Delta ASDA-AB is a 100 W to 3 kW AC servo drive series designed for specific Delta ECMA servo motors. In feeding, indexing and positioning applications, the drive can follow an external pulse train or call up one of eight stored positions through its digital inputs.

Supply codes and ECMA motor matching

The ASD-A0411-AB and ASD-A0421-AB are both rated at 400 W. The first is a 110 V class model and the second is a 220 V class model. The 110 V single-phase options cover 100 W, 200 W and 400 W. The 2 kW ASD-A2023-AB and 3 kW ASD-A3023-AB are 220 V three-phase models. Confirm panel compatibility using the complete drive code and the voltage and phase on its nameplate.

Delta lists several motors for the ASD-A0421-AB, including the ECMA-C30604□S and ECMA-C30804□7. When selecting a motor, compare the frame, shaft and brake options alongside the power rating. The published encoder resolution is 2,500 pulses per revolution. Verify feedback compatibility by checking the motor code, CN2 connection and cable together as components of the servo axis.

Pt and Pr positioning modes

In Pt mode, the position command enters CN1 as an external pulse train. P1-00 sets the pulse format, and P1-44/P1-45 set the first electronic gear ratio. The manual specifies a maximum of 500 kpps for differential input and 200 kpps for open-collector input. After drive replacement, measure the actual axis travel for a known command to check positioning accuracy.

In Pr mode, eight positions are stored in parameter pairs P1-15–P1-30. POS0–POS2 select the position and CTRG triggers the move. The drive also offers speed and torque control modes. Check the analog references and digital inputs, the PLC’s NPN/PNP output type and the travel limit switches against the machine schematic. CN3 supports selectable RS-232, RS-485 or RS-422. Chapter 8 covers serial Modbus settings.

Editor’s Note

1. Get the complete code on the quote. “400 W AB” can refer to a 110 V or 220 V unit. Request both drive and motor nameplates with the quote. During a used equipment inspection, look for motor shaft play, damaged connector latches and signs of oil ingress.

2. Record the settings for the mode in use. When backing up the drive configuration, capture P1-01 in both modes. For Pt, record the pulse format and gear ratio. For Pr, record the position values, input assignments and the absolute or relative positioning setting in P1-33.

3. Trace Pr selection and triggering separately. If the axis goes to the wrong target, monitor POS0–POS2 and then the timing of CTRG in the PLC. Confirm the target and travel direction before changing loop gains or evaluating auto-tuning.

4. Check both ends of the encoder cable. Save the alarm history from P4-00–P4-04. With the system safely isolated, inspect the connectors at CN2 and at the motor. For intermittent faults, also check grounding, shield termination and signal cable routing.

5. Record what the axis was doing when it faulted. Note the load and deceleration time when a stopping fault recurs. If the fault involves regenerative energy, compare the braking resistor with the table for the exact drive model.

6. Ask to see the command mode in the used-unit test. For a Pr application, ask for a test recording that shows a stored position being selected and triggered. For a Pt axis, ask to see the response to an external pulse command, including direction and stopping.

User manual

Delta ASDA-AB User Manual (PDF) · English, November 2014, 343 pages. See Section 1.3 for motor matching, Chapter 3 for wiring, Chapter 6 for Pt/Pr settings and Chapter 9 for alarms.

Related Delta equipment

Delta ECMA motors · Servo cables · Encoder connectors · Servo I/O connections · Servo braking resistors

Delta ASDA-A · Delta ASDA-A2-E · Delta ASDA-A2R · Delta ASDA-B2 · Delta AS PLC · Delta AH motion controllers

Delta Servo Manuals · Delta Servo Drives · Used Servo Drives

External reference — Delta Electronics manual